Injection port for contrast media facilitates fluoroscopic visualization.

Sterile single-use design for convenience both before and after procedures.

Eight-wire basket

designed for the

capture and removal

of small stones.

Four-wire basket

design for

versatile retrieval

Rotation mechanism and

bullet-shaped tip

Wire guided ability for

superior insertion capability

The FG-V411Q and FG-V412Q are designed to be wire 
guided with the wire passing only through the distal end 
of the basket. This makes it possible to insert the basket 
into a small incision on the papilla, and allows selective 
insertion into the intrahepatic bile duct. In addition, 
these baskets have the same expansion capability as our 
conventional models(FG-401Q/FG-22Q-1 etc) because 
the guidewire is only attached to the basket’s distal tip. 

For versatile retrieval of a 
wide range of stones, the 
TetraCatchV features a 
standard four-wire retrieval 
basket configuration.

   

The FlowerBasketV has 
eight wires on the distal side 
and four wires on the 
proximal side. The eight-wire 
section allows the precise 
retrieval of small stones while 
the four-wire section makes 
it easier to release them.

   

V-Marking

The exclusive V-Marking is located on the proximal side of the sheath. When 
this marking reaches the channel port on the scope’s control section, it indicates 
that the device tip has reached the distal end of the scope and the V-Groove 
forceps elevator may be lowered. When  withdrawing the device from the scope, 
the same marking indicates when to raise the elevator to lock the guidewire.

The Innovative V-System Design Lets You Proceed 
with Confidence and Efficiency

Indicates when to raise and lower 
the V-Groove forceps elevator.

Revolutionary V-System Device Exchange 
is Now Combined with New Basket Designs, 
a Rotation Mechanism, and Wire Guided Access

Unique Distal Eight-wire Basket is 
Ideal for Retrieval of Small Stones 
and with Four Proximal Wires to 
Facilitate Release of Captured Stones

Standard Four-wire Basket

Meets Most Stone Retrieval

Requirements in the Bile and

Pancreatic Ducts

The rotatable basket  (FG-V401QR / FG-V402QR ) 
allows the retrieval of small stones, especially 
floating stones or stones located in the lower bile 
duct  above the papilla.  The bullet-shaped tip 
ensures smooth insertion into the bile duct.

   

The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary 
V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange 
of catheters, and enhances cannulation capability.

Содержание Single Use Cannula V StarTip V

Страница 1: ...Single Use Cannula V Single Use Cannula V...

Страница 2: ...when to raise the elevator to lock the guidewire C Hook Now endoscopists have the option to manipulate guidewires and devices V Marking Indicates when to raise and lower the V Groove forceps elevator...

Страница 3: ...Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Au...

Страница 4: ...Single Use 3 Lumen Extraction Balloon V...

Страница 5: ...that the device tip has reached the distal end of the scope and the V Groove forceps elevator may be lowered When withdrawing the device from the scope the same marking indicates when to raise the el...

Страница 6: ...yringes for reliable inflation Multiple balloon sizing Injection Lumen 0 035 Guidewire Lumen Air Lumen For easy confirmation of balloon position during fluoroscopy two radiopaque bands are incorporate...

Страница 7: ...ions design and accessories are subject to change without any notice or obligation on the part of the manufacturer Shinjuku Monolith 3 1 Nishi Shinjuku 2 chome Shinjuku ku Tokyo 163 0914 Japan Postfac...

Страница 8: ...Single Use Retrieval Basket V Single Use Retrieval Basket V...

Страница 9: ...ng is located on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and...

Страница 10: ...ngapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005...

Страница 11: ...Single Use 2 Lumen Sphincterotome V Single Use 3 Lumen Sphincterotome V...

Страница 12: ...ed on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and the V Groov...

Страница 13: ...ases in which cannulation is difficult due to strictures or when insertion into the minor papilla is required The tapered tip CleverCut3V is compatible with a 0 025 diameter guidewire The distal ends...

Страница 14: ...t Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A Spacifications Model...

Страница 15: ...DISPOSABLE GUIDEWIRE...

Страница 16: ...sign Lets You Proceed with Confidence and Efficiency Schematic of the V Groove locking mechanism V System device replacement procedure Conventional scope TJF 160 V System scope TJF 160V LinearGuideV G...

Страница 17: ...5 2 and 5 2 5 2 when used with an Olympus sphinctetorome Removal of the guidewire is not necessary during sphincterotomy All Designs are Optimized to Assure Smooth Efficient Guidance of Devices to th...

Страница 18: ...oint Office Tower Singapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng Dis...

Отзывы: