Olympus Single Use Cannula V StarTip V Скачать руководство пользователя страница 12

Exceptional Cutting Performance and Easy, 
Fast Exchange Capability for Enhanced Efficiency 
in ERCP Sphincterotomy

Distal marking on the sheath for 
improved view field visibility

The distal marking on the sheath 
clearly indicates both the center and 
cutting position of the knife.

Injection lumen

Guidewire lumen

Cutting wire lumen

Sheath design for stable and 
reliable cannulation

Designed to optimize insertion into the 
scope, this sheath is narrower at the distal 
end and thicker at the proximal end. 
This improves handling and ensures smoother 
insertion, while also providing excellent 
cannulation capability into the papilla.

Easy identification 
of ports

The guidewire port and the 
injection port are easily 
identified by symbols.

Unique Device Design and Attention to Every Detail of 
The CleverCut2V and CleverCut3V Sphincterotomes

CleverCut coating enhances safety

Olympus’s signature CleverCut coating on the 
proximal end of the cutting wire minimizes damage 
to the surrounding tissue.  In addition, 
CleverCut Coating reduces the risk of electrical 
contact between the wire and the endoscope.

The CleverCut3V wire, injection lumen and guidewire 
lumen are arranged to allow easier orientation of the 
cutting wire for effective sphincterotomy.  Since the 
injection lumen and the guidewire lumen are completely 
separate, contrast media can be smoothly injected with 
a guidewire in place.

The CleverCut3V offers excellent 
orientation and smooth injection 

Features that display 

the icon on the top 

are available with 

CleverCut2V

 

double-lumen 

models. Those 

displaying the 

bottom icon are 

available with 

CleverCut3V 

triple-lumen models.

V-Marking

The exclusive V-Marking is located on the proximal side of the sheath. When 
this marking reaches the channel port on the scope’s control section, it indicates 
that the device tip has reached the distal end of the scope and the V-Groove 
forceps elevator may be lowered. When  withdrawing the device from the scope, 
the same marking indicates when to raise the elevator to lock the guidewire.

The V-Sheath allows the endoscopist complete device control or, if preferred, 
device control may be given to the assistant.  The unique device design allows 
the guidewire sheath and injection sheath/handle to be separated.  This forked 
sheath design allows either the endoscopist or the assistant to control the device.

V-Sheath

The Innovative V-System Design Lets You Proceed 
with Confidence and Efficiency

V-System device replacement procedure 

C-Hook

The convenient C-Hook allows the device handle to be attached to the 
endoscope’s control section, putting it within easy reach of the endoscopist. 
With the device handle right at hand, the endoscopist can maneuver the 
guidewire, inject contrast media, and manipulate the handle — all while keeping 
a grip on the scope control section.

Indicates when to raise and lower 
the V-Groove forceps elevator.

Device control by the endoscopist 
or the assistant.

Confirm the position of the V-Marking 

  on the V-System EndoTherapy accessory.  

Now endoscopists have the option to 
manipulate guidewires and devices.

When the V-Marking is completely visible 

  above the instrument channel port, lift the 

   forceps elevator to lock the guidewire.

The guidewire is now locked 

  into the V-Groove.

Completely remove the device.

The V-System is a complete system that integrates Olympus endoscopes and EndoTherapy devices. The revolutionary 
V-System design offers the option of guidewire manipulation by the physician or the assistant, allows easier exchange of 
catheters, and enhances cannulation capability.

Содержание Single Use Cannula V StarTip V

Страница 1: ...Single Use Cannula V Single Use Cannula V...

Страница 2: ...when to raise the elevator to lock the guidewire C Hook Now endoscopists have the option to manipulate guidewires and devices V Marking Indicates when to raise and lower the V Groove forceps elevator...

Страница 3: ...Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Au...

Страница 4: ...Single Use 3 Lumen Extraction Balloon V...

Страница 5: ...that the device tip has reached the distal end of the scope and the V Groove forceps elevator may be lowered When withdrawing the device from the scope the same marking indicates when to raise the el...

Страница 6: ...yringes for reliable inflation Multiple balloon sizing Injection Lumen 0 035 Guidewire Lumen Air Lumen For easy confirmation of balloon position during fluoroscopy two radiopaque bands are incorporate...

Страница 7: ...ions design and accessories are subject to change without any notice or obligation on the part of the manufacturer Shinjuku Monolith 3 1 Nishi Shinjuku 2 chome Shinjuku ku Tokyo 163 0914 Japan Postfac...

Страница 8: ...Single Use Retrieval Basket V Single Use Retrieval Basket V...

Страница 9: ...ng is located on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and...

Страница 10: ...ngapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005...

Страница 11: ...Single Use 2 Lumen Sphincterotome V Single Use 3 Lumen Sphincterotome V...

Страница 12: ...ed on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and the V Groov...

Страница 13: ...ases in which cannulation is difficult due to strictures or when insertion into the minor papilla is required The tapered tip CleverCut3V is compatible with a 0 025 diameter guidewire The distal ends...

Страница 14: ...t Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A Spacifications Model...

Страница 15: ...DISPOSABLE GUIDEWIRE...

Страница 16: ...sign Lets You Proceed with Confidence and Efficiency Schematic of the V Groove locking mechanism V System device replacement procedure Conventional scope TJF 160 V System scope TJF 160V LinearGuideV G...

Страница 17: ...5 2 and 5 2 5 2 when used with an Olympus sphinctetorome Removal of the guidewire is not necessary during sphincterotomy All Designs are Optimized to Assure Smooth Efficient Guidance of Devices to th...

Страница 18: ...oint Office Tower Singapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng Dis...

Отзывы: