background image

EN 14

EN

2. Advance Check of the Case

Advance check before use

This Case has been the subject of thorough quality control for the parts 
during the manufacturing process and thorough function inspections 
during the assembly. In addition, a water pressure test is performed with 
a water pressure tester for all products to confirm that the performance 
conforms to the specifications.
However, depending on the carrying and storage conditions, the 
maintenance status, etc., the waterproof function may be damaged.
Before using, always perform the following advance checks.

Advance Check

1

Before installing the digital camera in the Case, immerse the empty 
Case to confirm that there is no water leakage. 
We recommend to immerse the empty Case to the intended water 
depth, however, if you cannot perform this way, check the Case by 
referring “Water Leakage Test” (P.18).

2

Main causes of water leakage are as follows.

• The O-ring has not been installed.
• A part of the O-ring or the entire O-ring is outside the specified 

groove.

• O-ring damage, cracks, deterioration or deformation
• Sand, fibers, hair or other foreign matter sticking to the O-ring, the 

O-ring groove or the O-ring contact surface on the front lid

• Damage to the O-ring groove or the O-ring contact surface on the 

front lid

• Catching of the strap, silica gel, etc. when closing the Case

Perform the test after the above causes have been eliminated.

CAUTION:

If a leak is detected in normal handling, do not use the Case and contact 
Olympus.

VM9754TA-01-01-PT-055-Inst-EN.book  Page 14  Monday, January 7, 2013  2:53 PM

Содержание PT-055

Страница 1: ...PT 055 Instruction Manual PT 055 2013 Printed in China http www olympus com VM975401 PT 055_1 4 fm 1...

Страница 2: ...rage after use zOLYMPUS IMAGING CORP shall in no way be responsible for accidents involving immersion of a digital camera in water In addition expenses incurred for damage of internal materials or los...

Страница 3: ...ttery in the digital camera housed in this product Storage with a battery inserted may lead to leakage of the battery liquid and fire 3 If leakage of water should occur with a camera installed in this...

Страница 4: ...o vibrations Locations with high temperature and humidity or with severe temperature changes Locations with volatile substances 3 Opening and closing at locations with much sand dust or dirt may impai...

Страница 5: ...fter taking pictures in the water it may cause the loss of transparency of the lens inside even if you insert the supplied silica gel to the Case when drying the camera is insufficient Chemicals which...

Страница 6: ...l camera 15 Check the digital camera 15 Open the Case 15 Load the digital camera 16 Make sure the camera is loaded properly 16 Seal the Case 17 Check the operation of the loaded camera 17 Perform the...

Страница 7: ...n 23 Remove the O ring 23 Remove any sand dirt etc 23 How to Apply Grease to the O ring 25 Install the O ring 26 Replace consumable parts 26 7 Appendix 27 Specifications 27 VM9754TA 01 01 PT 055 Inst...

Страница 8: ...r if accessories are missing or damaged O ring remover Hand strap Lens cap Silica gel 1g Silicone grease Case body Check that the O ring is installed LCD hood on the body LCD hood strap Optical fiber...

Страница 9: ...user 3 Shutter lever 4 ON OFF button 5 Accessory mount 6 Front lid 7 Open close dial 8 Lock knob 9 Lens ring 0 LCD inner hood a O ring b Tripod seat a b 2 4 3 5 7 9 8 0 1 6 VM9754TA 01 01 PT 055 Inst...

Страница 10: ...pad T k MENU button l Arrow pad W m LCD monitor window n Rear lid Memo The Case operation parts marked by corresponds to the operation parts of the digital camera When the operation parts of the Case...

Страница 11: ...se body How to use the hand strap Pass your hand through the hand strap and adjust the length with the stop button Hand strap ring Hand strap Installation illustration Installation completed stop butt...

Страница 12: ...Removal Remove the LCD hood from the guides above and below the LCD monitor window one after the other by widening the LCD hood Mounting and removing the lens cap Fit the lens cap onto the lens ring a...

Страница 13: ...tional PTCB E02 How to install 1 Attach the optical fiber cable adapter to the diffuser shown in the figure below 2 Put the underwater optical fiber cable plug all the way into the optical fiber cable...

Страница 14: ...is no water leakage We recommend to immerse the empty Case to the intended water depth however if you cannot perform this way check the Case by referring Water Leakage Test P 18 2 Main causes of water...

Страница 15: ...al camera is loaded without removing the strap the strap may get caught between the Case lids and may cause water leakage Open the Case 1 Slide the lock knob towards the arrow direction 1 of figure be...

Страница 16: ...he specified location Is the O ring attached properly to the opening on the Case Is there any dirt or foreign matter on the O ring or the O ring contact surface on the front lid Is the waterproof func...

Страница 17: ...utton on the Case and confirm that the camera turns ON OFF 2 Press the shutter lever on the Case and confirm that the camera shutter releases Also operate other control buttons on the Case and confirm...

Страница 18: ...e the Case for only 3 seconds and check that no water drop etc to the Case Next immerse the Case for 30 seconds and check that no water drop etc to the Case Then immerse the Case for 3 minutes operate...

Страница 19: ...flash it can also be enabled if required for example when shooting a manta ray HUnderwater Macro Suitable for close up shooting of small fish and other underwater creatures Natural colors of the unde...

Страница 20: ...right arrow pad to select the shooting scene and then press the OK AFL button When the Underwater Wide Angle 1 or Underwater Macro mode is selected you can easily lock the focus position AF lock oper...

Страница 21: ...oft cloth not leaving any fibers to thoroughly wipe any waterdrop etc from the joint between the front and rear lid the shutter lever the palm grips and the open close dial CAUTION When waterdrops rem...

Страница 22: ...ur hands or gloves are free of sand fibers etc Do not open or close the Case at locations where there is water spray or sand Take care not to touch the digital camera or the battery with hands wet wit...

Страница 23: ...the inserted O ring remover below the O ring Be careful not to scratch the O ring groove with the tip of the O ring remover 3 Hold the O ring with your fingertips after it has come out of the groove...

Страница 24: ...t underwater for the first time When a sharp object is used to remove the O ring or to clean the inside of the O ring groove the Case and the O ring may be damaged and water leakage may occur Take car...

Страница 25: ...h that the O ring is not scratched and that its surface is flat If it is damaged in any way be sure to replace it with a brand new O ring 4 Apply lubricant on the O ring contact surface Use the lubric...

Страница 26: ...e Replace consumable parts The O ring is a consumable part Regardless of the number of times the Case is used it is recommended that the O ring be replaced with a new one at least once a year Deterior...

Страница 27: ...ompatible models Olympus digital camera STYLUS TG 830 Pressure resistance Depth of up to 45 m Main materials Body Polycarbonate Lens window Multiple coat glass Diameter of lens ring 52 mm Operating en...

Страница 28: ...ash UFL 1 Short arm PTSA 02 PTSA 03 Step up ring 52mm to 67mm PSUR 03 Underwater wide conversion lens PTWC 01 Underwater macro conversion lens PTMC 01 Maintenance kit PMS 02 O ring remover 2 PTAC 05 B...

Страница 29: ...VM9754TA 01 01 PT 055 Inst EN book Page 29 Monday January 7 2013 2 53 PM...

Страница 30: ...MEMO VM9754TA 01 01 PT 055 Inst KR book Page 30 Monday January 7 2013 3 15 PM...

Страница 31: ...VM9754TA 01 01 PT 055 Inst KR book Page 31 Monday January 7 2013 3 15 PM...

Страница 32: ...PT 055 Instruction Manual PT 055 2013 Printed in China http www olympus com VM975401 PT 055_1 4 fm 1...

Отзывы: