background image

5

2

電源ユニットの接続

(Figs. 2,3)

電源ユニットのメインスイッチが 

(OFF)になっていることを確認してか

ら接続してください。

1 )コネクタ①をOUTPUTコネクタ②に確

実に差込んでください。

・ 白色LEDユニット→

表示のコネクタへ

・ 緑色LEDユニット→

表示のコネクタへ

2 )電源インレット③に電源コード④を取

付け、電源プラグ⑤を電源コンセント
⑥に差込みます。

アース付3芯コンセントに必ず接続して
ください。コンセントのアースが未接
続の場合は、当社の意図する電気安全
性能が確保できません。

2

Connecting the Power
Supply Unit

(Figs. 2 & 3)

Ensure that the main switch of the Power
Supply Unit is set to “   ” (OFF) before
proceeding to the connection.

1. Insert the connector @ firmly into the

OUTPUT connector ².
 · White LED Unit: Insert into the connector

marked       .

 · Green LED Unit: Insert into the connector

marked       .

2. Connect the power cord | into the power

inlet receptacle ³, and connect the power
plug 

of the power cord into the power

outlet 

6

.

Connect the provided power cord
correctly and ensure that the grounding
terminal of the power supply and that of
the 3-conductor wall outlet are properly
connected. If the equipment is not
grounded, Olympus can no longer warrant
the electrical safety performance of the
equipment.

Fig. 2

Fig. 3

@

²

³

|

5

6

Downloaded from 

ManualsNet.com

 search engine

Содержание MM6-ILG

Страница 1: ...MM6 ILW ILG ILPS 2 To ensure the safety obtain optimum performance and to fa miliarize yourself fully with the use of this attachment we recommend that you study this manual thoroughly before operatin...

Страница 2: ...his product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against har...

Страница 3: ...power supply unit incorporates high voltage parts inside Do not open the cover of this unit to prevent electric shock Notes on the LED Light Emitting Diode Safety It is discommended to stare at the li...

Страница 4: ...unit as instructed in this manual The caution messages in this manual carry the following symbol Caution for prevention of injury of the user or damage to the equipment in cluding properties in the su...

Страница 5: ...ontrol Turn clockwise to increase the light intensity Transmitted light illumination Reflected light illumination NOMENCLATURE White Green LED Unit MM6 ILW ILG LED light emitter block Connector Power...

Страница 6: ...ed Olympus can no longer warrant the electrical safety performance of the equipment ASEMBLY 1 Installing the LED Light Emitter Block Fig 1 1 When installing the White LED Unit MM6 ILW insert it into t...

Страница 7: ...t Insert into the connector marked 2 Connect the power cord into the power inlet receptacle and connect the power plug 5 of the power cord into the power outlet 6 Connect the provided power cord corre...

Страница 8: ...t temperature 20 C light intensity level 50 Power Supply Unit Model MM6 ILPS 2 System Constant current lighting 2 circuits Output current variation 0 to 630 mA Rated supply voltage 100 240 V AC 0 2 0...

Страница 9: ...power supply cord should be certified by one of the agencies listed in Table 1 or comprised of cordage marked with an agency marking per Table 1 or marked per Table 2 The fittings are to be marked wi...

Страница 10: ...band f r Elektrotechnik VE Danmarks Elektriske Materialkontroll DEMKO National Standards Authority of Ireland NSAI Norges Elektriske Materiellkontroll NEMKO Asociacion Electrotecnica Y Electronica Esp...

Страница 11: ...Downloaded from ManualsNet com search engine...

Страница 12: ...Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan Printed in Japan 20210607 M0000 AX7969 07 Downloaded from ManualsNet com search engine...

Отзывы: