This instruction manual is for the Olympus LED light source for light guide.
To ensure the safety, obtain optimum performance and to familiarize yourself fully with the use of 
this product, we recommend that you study this manual thoroughly before operating this product, 
and always keep this manual at hand when operating this product.
Retain this instruction manual in an easily accessible place near the work desk for future reference.
For details of products included in the configuration of this system, see page 8.

LED light source for light guide

LG-LSLED

Optical Microscope Accessory

Содержание LG-LSLED

Страница 1: ...duct we recommend that you study this manual thoroughly before operating this product and always keep this manual at hand when operating this product Retain this instruction manual in an easily access...

Страница 2: ...y the party responsible for compliance could void the user s authority to operate the product FCC Supplier s Declaration of Conformity Hereby declares that the product Product name Optical Microscope...

Страница 3: ...ching the filter Optional 10 3 Adjusting LG DI LG DFI Dual light guide Dual light guide 11 4 Troubleshooting 12 5 Specifications 13 6 Assembly 15 6 1 Attaching the light guide 15 1 Attaching the light...

Страница 4: ......

Страница 5: ...cedure Loosen the clamping screw A using the screwdriver Remove the product B TIP NOTE CAUTION B A The following symbols are used in this instruction manual WARNING Indicates a potentially hazardous s...

Страница 6: ...d confirmation before use This product includes the following items If any item is missing or damaged contact Olympus Instruction manual for LG LSLED this instruction manual AC adapter This product is...

Страница 7: ...ower cord from the power cord connector on the product or from the power outlet Install the product at the location where you can reach the power cord connector or the power outlet at hand to disconne...

Страница 8: ...le when turning ON the LED unit be sure to secure the space of 10 cm or more between the flammable light absorbing materials and the distal end of such light guide Otherwise it may cause fire or burns...

Страница 9: ...Seesaw type is the type of switch where ON or OFF is selected by pressing it to ON or OFF side Indicates that the seesaw type main switch is OFF Label position and instruction The labels are attached...

Страница 10: ...dust or vibrations For conditions of operating environments see 5 Specifications P 13 For products option attachable to this product see 1 System diagram P 8 The use of this product in combination wit...

Страница 11: ...ce the absolute alcohol is highly flammable it must be handled carefully Be sure to keep it away from open flames or potential sources of electrical sparks For example the electrical equipment that is...

Страница 12: ...6 1 SZX2 ILLC10 1 Coaxial illuminator SZX series 1 SZ2 series 1 SZX LGR66 2 Ring light guide adapter for SZX SZ LGR66 Ring light guide adapter for SZ LG SF 1 Flexible light guide LG LSLED LED light so...

Страница 13: ...g portions Light intensity adjustment knob P 10 Lock screw P 15 Carrying handle Power socket P 18 Filter slider P 10 This section describes the nomenclature of main operating portions of the product F...

Страница 14: ...er with a diameter of 28 mm and a thickness of 2 mm can be attached Use the optional 28LBA15 LBA filter if you want to change to the light bulb color CAUTION TIP Remove the cap that covers the distal...

Страница 15: ...may be impacted adversely or the filter slider may be damaged 3 NOTE 3 Adjusting LG DI LG DFI Dual light guide Dual light guide A A B 1 Illuminate the light to the sample from the position where the...

Страница 16: ...o be disconnected Connect the light guide to the LG LSLED LED light source for light guide and the microscope properly 15 The filter is engaged in the light path Pull out the filter slider to the clic...

Страница 17: ...Maximum valid fiber diameter 9 mm Total luminous flux when LG SF is combined 360 lm or more Filter slider Attachable filtersize 28 mm Thickness 2 mm Dimension 114 W x 231 D x 137 H mm Weight Approx 2...

Страница 18: ...g Other light guides Item Specifications Product name LG R66 LG DI LG DFI LG DF LG SF Corrugated tube Type Flexible tube Interlock tube Flexible tube Interlock tube Flexible tube Flexible tube Length...

Страница 19: ...e is not attached yet set the power to OFF in order to prevent looking at the LED light directly Do not use light guides other than the exclusive light guides For details of the exclusive light guides...

Страница 20: ...face of LG R66 and tighten the clamping screw D using the Allen screwdriver 1 2 3 4 3 Attaching LG R66 Ring light guide 1 3 B A C SZ61 SZ51 Screw in SZ LGR66 Ring light guide adapter for SZ A complete...

Страница 21: ...guide socket with optional LG KLADP Socket for KL light guide Before replacing the light guide socket be sure to set the power to OFF and wait until the light guide is sufficiently cooled down CAUTIO...

Страница 22: ...u use the power plug it into 3 core outlets with grounds If the outlet is not grounded the electric safety performance intended by Olympus cannot be assured Do not apply excess force to the power cord...

Страница 23: ...locally the power supply cord which is approved by one of the agencies mentioned in Table 1 please use replacements approved by any other equivalent and authorized agencies in your country Country Ag...

Страница 24: ...Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 sterreichischer Verband f r Elektrotechnik VE VE HAR 30 10 50...

Страница 25: ...LG LSLED MEMO...

Страница 26: ...MEMO...

Страница 27: ......

Страница 28: ...AX9376 04 Issued in March 2019 Distributed by Manufactured by Shinjuku Monolith 2 3 1 Nishi Shinjuku Shinjuku ku Tokyo 163 0914 Japan www olympus global com...

Отзывы: