DMTA017-01EN, Rev. F, August 2016
Chapter 1
18
When loosened, the wheel assembly slides freely on the frame, and can be
temporarily removed and reinstalled in a different configuration. For example,
the frame can be positioned to extend outside the limits of the wheels, which is
well-suited to hard-to-reach areas, such as pipe-to-component welds (see
Figure 1-6 on page 18).
Figure 1
‑
6 Alternative scanner configuration
Preamplifier
If necessary, a preamplifier (often required for TOFD inspections) can be mounted
on the frame. In the example shown in Figure 1-6 on page 18, an Olympus
TRPP 5810 pulser/preamplifier is used. A bracket is required to mount the
TRPP 5810 on HSMT scanners. This bracket is included with some TRPP 5810
packages, and can also be ordered separately (part number: HSMT-A-BRK5810
[U8779088]).
Preamplifier (optional)
Sliding the wheel assembly to change the frame
configuration