199
SYMPTOM
The picture is out of focus.
POSSIBLE CAUSES
6
The Manual focus was
used with the wrong
focal range.
7
The subject was dark
and the AF assist lamp
was turned off.
CORRECTIVE ACTION
6
Use the right Manual focus for
the distance.
7
Set the AF assist lamp to on.
REF. PAGE
P. 94
P. 157
SYMPTOM
The picture is too bright.
POSSIBLE CAUSES
1
The flash mode was set
to the Fill-in flash mode.
2
The subject was
excessively illuminated.
CORRECTIVE ACTION
1
Select a flash mode other
than the Fill-in flash mode.
2
Use spot metering. Adjust the
exposure compensation or
change the camera position
toward the subject.
REF. PAGE
P. 107
P. 99
SYMPTOM
The picture is too dark.
POSSIBLE CAUSES
1
The flash was blocked
by a finger.
2
The subject was out of
the working range of the
flash.
3
The flash mode was set
to the Off mode.
4
The subject was too
small and was backlit.
5
The Sequence mode
was used.
CORRECTIVE ACTION
1
Hold the camera correctly,
keeping your fingers away
from the flash.
2
Shoot within the flash working
range. Or, use an external
flash.
3
Check the flash mode before
shooting.
4
Set the flash to Fill-In mode.
Or, use the Spot metering
mode.
5
Higher shutter speeds are
used when the Sequence
mode is selected which may
result in pictures that are
darker than usual.
REF. PAGE
P. 66
P. 106
P. 112
P. 107
P. 107
P. 100
P. 118
Содержание CAMEDIA C-2100 Ultra Zoom
Страница 30: ...30...
Страница 128: ...128...
Страница 166: ...166...
Страница 179: ...7 TRANSFERRING PICTURES TO A COMPUTER...
Страница 191: ...191 You can easily compose images with templates in CAMEDIA Master Composing Images with Templates...
Страница 192: ...192...
Страница 193: ...8 MISCELLANEOUS...
Страница 211: ...211...