DMTA-10004-01EN, Rev. D, November 2016
Chapter 7
98
To achieve accurate boiler tube and internal oxide scale thickness readings, remove
any oxide scale or coating from the external surface of the boiler tube.
The minimum internal oxide thickness that the 38DL PLUS can measure depends on
the material sound velocity but is approximately 0.254 mm (0.010 in.) with the M2017
transducer or 0.152 mm (0.006 in.) with the M2091 transducer. The 38DL PLUS only
displays the thickness of the steel boiler tube when the internal oxide scale thickness
is below the minimum measurement capability or when it is exfoliated (disbonded)
from the inside of the boiler tube.
Figure 7-5 on page 98 shows a waveform from a sample in which the internal oxide
layer is disbonded from the boiler tube. Because the oxide is disbonded, sound energy
does not travel into the internal oxide layer, and only a single reflected echo from the
inside of the boiler tube appears. When the internal oxide is thinner than 0.25 mm
(0.010 in.), the waveform looks almost identical. The steel/oxide interface is so close in
time to the echo from the inside of the oxide that it cannot be separated from the total
back-wall echo and will produce a single echo.
Figure 7
‑
5 Measurement screen for a disbonded oxide layer
NOTE
Absence of a
steel/oxide echo
Tube thickness
Oxide layer thickness
Single echo from the
inside of boiler tube
Содержание 38DL PLUS
Страница 9: ...DMTA 10004 01EN Rev D November 2016 Table of Contents ix Index 297 ...
Страница 10: ...DMTA 10004 01EN Rev D November 2016 Table of Contents x ...
Страница 28: ...DMTA 10004 01EN Rev D November 2016 Important Information Please Read Before Use 16 ...
Страница 30: ...DMTA 10004 01EN Rev D November 2016 Introduction 18 ...
Страница 50: ...DMTA 10004 01EN Rev D November 2016 Chapter 2 38 ...
Страница 60: ...DMTA 10004 01EN Rev D November 2016 Chapter 3 48 ...
Страница 102: ...DMTA 10004 01EN Rev D November 2016 Chapter 6 90 ...
Страница 221: ...DMTA 10004 01EN Rev D November 2016 Using the Datalogger 209 f Press MEAS to exit the minimum review ...
Страница 222: ...DMTA 10004 01EN Rev D November 2016 Chapter 11 210 ...
Страница 254: ...DMTA 10004 01EN Rev D November 2016 Chapter 13 242 ...
Страница 274: ...DMTA 10004 01EN Rev D November 2016 Chapter 14 262 ...
Страница 286: ...DMTA 10004 01EN Rev D November 2016 Chapter 15 274 ...
Страница 294: ...DMTA 10004 01EN Rev D November 2016 Appendix A 282 ...
Страница 300: ...DMTA 10004 01EN Rev D November 2016 Appendix C 288 ...
Страница 306: ...DMTA 10004 01EN Rev D November 2016 List of Figures 294 ...