In the Event of an Alarm

15

G

In the Event of an Alarm

Signalling (Master is Triggered)

The illustration indicates the sequence of notification when the smoke detector set-up as the master
is triggered.

If you have linked the smoke detectors to each other without an alarm system, notification oc­
curs accordingly without an alarm system.

The slaves issuing the alarm are switched off automatically independent of the master after
10 minutes.

Содержание RTX 200

Страница 1: ...R RTX 200 Smoke Detector Operating Manual 01 07 2015 gb v1 0...

Страница 2: ......

Страница 3: ...nformation 7 Operating Elements 10 Registering Without Alarm System 11 Registering With Alarm System 13 In the Event of an Alarm 15 Installation 19 Guarantee 22 Information on Disposal 22 Technical Da...

Страница 4: ......

Страница 5: ...r other smoke alarms then raise the actual alarm A condition for complying with the intended use is that the equipment is installed correctly and the information in the manual is observed and maintain...

Страница 6: ...monitors a limited area Therefore install a sufficient number of smoke detectors to ensure optimum protection The smoke detectors only operate correctly with fully functional correctly inserted batte...

Страница 7: ...atteries which are not approved by the manu facturer The use of inappropriate batteries can cause loss of function of the smoke detector Only use batteries approved by the manufacturer 1 Remove the sm...

Страница 8: ...d the environment from any harm WARNING Risk of suffocation Children can swallow small parts packaging and protective foils Keep the product and packaging out of reach of children WARNING Risks to hea...

Страница 9: ...em to pollute the environment Batteries may contain toxic ecologically hazardous heavy metals CAUTION Hearing damage through loud alarm signal The alarm signal is loud and could cause hearing damage O...

Страница 10: ...ences Harmful environmental influences such as exposure to smoke dust vibration chemicals moisture heat and direct sunlight could damage the product Prevent exposing the device to environmental influe...

Страница 11: ...Operating Elements 10 G Operating Elements 3 2 1 1 4 5 1 Base 2 Code button 3 Lock 4 Smoke detector housing 5 Test button with LED...

Страница 12: ...e detectors registered as slaves on the master The master slave operation ensures that when an alarm is triggered all the smoke detectors con nected are also triggered We recommend setting up the wire...

Страница 13: ...re registra tion process is completely finished 3 The alarm signal sounds the smoke detector is set up as the master Registering the Smoke Detector as a Slave Further smoke detectors can be registered...

Страница 14: ...ystem Registering the Smoke Detectors on the Alarm System One of the smoke detectors must be registered as the master on an alarm system from the Protect series The smoke detectors must be connected t...

Страница 15: ...e detector The battery clip is reverse polarity proof 3 The SmokeSensormessage followed by a number appears in the display of the alarm system 4 Change the entry in the alarm system as necessary Compl...

Страница 16: ...equence of notification when the smoke detector set up as the master is triggered If you have linked the smoke detectors to each other without an alarm system notification oc curs accordingly without...

Страница 17: ...notification when a smoke detector set up as a slave is triggered If you have linked the smoke detectors to each other without an alarm system notification oc curs accordingly without an alarm system...

Страница 18: ...ront of your mouth and nose Follow the escape routes indicated Close all doors and windows which can be accessed to pre vent the smoke and fire spreading further Call the fire service using the approp...

Страница 19: ...elopments in the area being moni tored Deactivate the alarm by ventilating the room in which the smoke detector has been triggered Or Deactivate the alarm via the alarm system base unit refer to the o...

Страница 20: ...where an attic has been upgraded to a living area Inappropriate Installation Locations The smoke detector must not be installed in the vicinity of electrical devices such as energy saving lamps elect...

Страница 21: ...r on jointless smoke impervious ceilings Install the smoke detector directly underneath the ceiling surface Always install the smoke detector horizontally even with sloping ceilings The distance betwe...

Страница 22: ...the base 1 to the ceiling at the chosen installation location using two screws approx 80 mm apart If necessary use dowels as additional fixation material 3 Ensure that all the smoke detectors in are c...

Страница 23: ...nger required must be disposed of separate from domestic waste in accordance with legal directives You are obliged to dispose of batteries and power packs at shops which sell batteries or collection p...

Страница 24: ...le standards EN 14604 2005 compliant with DIN 14676 CE Mark Olympia Business Systems Vertriebs GmbH Zum Kraftwerk 1 45527 Hattingen hereby declares that this device fulfils the requirements and compli...

Страница 25: ...ector and cause malfunctions It is possible that smoke can no longer be detected 1 Clean the surface of the housing regularly with a soft moistened lint free cloth 2 Clean the smoke inlet with a brush...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...Olympia Business Systems Vertriebs GmbH Zum Kraftwerk 1 45527 Hattingen...

Отзывы: