Example: PLU12 for 2.50 EUR belongs to department 1. 

Input 

Display 

Confirm by pressing 

h

 

P001  0,00 

 

 

1. PLU price and assignment: 
Set the key to PRG 

Press 

h

 

Enter the required PLU number, 

confirm by pressing 

f

12 

P12  0,12 

f

 

 

Now enter the PLU fixed price and 
the department assignment by 

pressing department key 

A

250 

2,50 

 

The next PLU automatically appears 
in the display. Proceed in the same 
way. 

P13  0,00 

 

 

Conclude input by pressing 

h

 

 

 

h

 

 

 

Example: PLU12 / DEP1 with free pricing permitted. 

Input 

Display 

Confirm by pressing 

P001  0,00 

 

 

2. PLU status: 
Note: This step is only necessary 
for PLUs which operate with free 
pricing. 
Status 0 = fixed price 
Status 1 = free pricing 
Set the key to PRG 

Press 

e

 

Enter the PLU no. to be pro-
grammed and confirm by pressing 

f

12 

P12  0,12 

f

 

 

Enter the PLU status, assign by 
pressing the corresponding depart-
ment key and confirm. 

0,01 

 

The next PLU automatically appears 
in the display. Proceed in the same 
way. 

 

P13  0,00 

 

 

Conclude input by pressing 

e

 

 

e

 

 

list of the programmed PLUs can be printed out. 

 

 

 

Confirm by pressing 

 

Set the key to PRG 
Send the print job by pressing 

f

 

 

 

f

 

 

Programming foreign currencies 

A maximum of 4 foreign currencies can be programmed. 

The following information must be entered for the programming process: 

 

Foreign currency identification: 1,2,3 or 4.  

 

Decimal places for the exchange rate (EXP): 0 to 8 decimal places are possible. 

 

Decimal places for the foreign currency (D.P.): 0 to 3 decimal places are possible. 

 

Exchange rate (RATE): 6-digit entry from 000001 to 999999. 

Содержание CM 70

Страница 1: ...CM 70 Quick Reference O Y L MPIA SINCE 1903 www olympia vertrieb de...

Страница 2: ...e la presente el fabricante declara que este aparato est conforme a lo dispuesto en las directivas y normas vigentes n De fabrikant verklaart hierbij dat het apparaat voldoet aan de bepalingen in de r...

Страница 3: ...ransportation of the cash register Transport locks Before the cash register can be put into operation remove any transport locks installed and store them for future use Important transport information...

Страница 4: ...the paper reel Replace the printer lid Paper reel The paper reel is required when the receipt should be wound onto it Change the system setting no 18 to 1 1 Open the printer lid 2 Remove the paper ree...

Страница 5: ...without memory deletion Z reports with memory deletion Programming Calculation Note Loss of data and jamming of the cash register are possible in Z and PRG operating modes Only use these modes when y...

Страница 6: ...10106 0101 06 m Programming the time Example 9 30 a m Input Display Confirm by pressing Set the key to PRG Enter the time as 4 digits hhmm Confirm by pressing h 0930 9 30 h Programming tax rates A max...

Страница 7: ...tax rates 000 DEP operates without fixed price free pricing alternatively Enter the fixed price Example 2 DEP1 is an itemised department at tax rate 2 7 and without a fixed price Input Display Confir...

Страница 8: ...ng Status 0 fixed price Status 1 free pricing Set the key to PRG Press e Enter the PLU no to be pro grammed and confirm by pressing f 12 P12 0 12 f Enter the PLU status assign by pressing the correspo...

Страница 9: ...to the 24 hour format Input Display Confirm by pressing Set the key to PRG The system options are entered as 2 or 3 digits The input is confirmed by pressing c 40 40 c Note The standard settings appe...

Страница 10: ...Total is deleted after Z1 financial report printout 0 Grand Total is not printed on the financial report 17 1 Grand Total is printed on the financial report 0 Calculator mode 18 1 Journal mode 0 Basi...

Страница 11: ...ed Conclude receipt p PPPPPPP q Foreign currency payment When all the PLUs have been registered press the p key to display and print the subtotal Enter the foreign currency identification and press k...

Страница 12: ...rices which have already been concluded can be reverted d Refund function is activated Complete the registration to be reverted Conclude with q Other functions m Cash register is opened e For cash pay...

Страница 13: ...0 CH 001 20 00 RA 001 20 00 PO 51 13 1 002 300 00 CA 400 00 13 45 009 Date Z1 counter 3 digit Number of registrations in department 1 Sales for department 1 Number of registrations in department 2 Sal...

Страница 14: ...he 4 digit password press n SEC CODE A password has been programmed for the clerk Enter the clerk number Then enter the 3 digit password Conclude by pressing R What to do if the cash register does not...

Страница 15: ...ug Check whether the paper roll is inserted correctly or there is a foreign body in the printer mechanism Remove it if present Caution Remove the foreign body very carefully Do not use a knife screwdr...