Error correction and void 

Faulty registrations can be corrected immediately after entry or later in the transaction. 

 
Error correction (direct): The last item entered during a registration can be corrected directly. 

 

Correction is completed 

 

 

 

 

Void (designated correction): Errors in amounts, PLU prices and department prices in transaction entered previously 
can be corrected during the registration. 

 

g

 

Void function is activated 

 

Press 

V

 

Enter same item or total of the department again.  

(Complete the registrations to be cancelled.) 

 
 

Correcting refund/returned goods: Registrations via amounts, PLU numbers or department prices which have already 
been concluded can be reverted. 

 

Refund function is activated  Complete the registration to be reverted 

Conclude with  

 

Other functions 

 

m

 

Cash register is opened 

 

For cash payments, enter the amount and press the key. 

 

For payments received on account, enter the amount and press the key. 

 

Following a registration or conclusion of the subtotal, a percentage discount can be entered.  

Example: Entry for 5%: 

5l

 

 

Training mode 

 

 

Input 

Display 

Confirm by pressing 

 

Start Training mode
Set the key to PRG 

Press 

6

 6 times, conclude by 

pressing 

q

666666 

6666,66 

q

 

 

 

To operate in Training mode
Set the key to REG 
 

To indicate that Training mode is active, a point  

appears at the 6th position in the display. 

Note: No reports can be printed in Training mode. 

 

Input 

Display 

Confirm by pressing 

 

End Training mode
Set the key to PRG 

Press 

5

 

 6 times, conclude by 

pressing 

q

555555 

5555,55 

q

 

Содержание CM 70

Страница 1: ...CM 70 Quick Reference O Y L MPIA SINCE 1903 www olympia vertrieb de...

Страница 2: ...e la presente el fabricante declara que este aparato est conforme a lo dispuesto en las directivas y normas vigentes n De fabrikant verklaart hierbij dat het apparaat voldoet aan de bepalingen in de r...

Страница 3: ...ransportation of the cash register Transport locks Before the cash register can be put into operation remove any transport locks installed and store them for future use Important transport information...

Страница 4: ...the paper reel Replace the printer lid Paper reel The paper reel is required when the receipt should be wound onto it Change the system setting no 18 to 1 1 Open the printer lid 2 Remove the paper ree...

Страница 5: ...without memory deletion Z reports with memory deletion Programming Calculation Note Loss of data and jamming of the cash register are possible in Z and PRG operating modes Only use these modes when y...

Страница 6: ...10106 0101 06 m Programming the time Example 9 30 a m Input Display Confirm by pressing Set the key to PRG Enter the time as 4 digits hhmm Confirm by pressing h 0930 9 30 h Programming tax rates A max...

Страница 7: ...tax rates 000 DEP operates without fixed price free pricing alternatively Enter the fixed price Example 2 DEP1 is an itemised department at tax rate 2 7 and without a fixed price Input Display Confir...

Страница 8: ...ng Status 0 fixed price Status 1 free pricing Set the key to PRG Press e Enter the PLU no to be pro grammed and confirm by pressing f 12 P12 0 12 f Enter the PLU status assign by pressing the correspo...

Страница 9: ...to the 24 hour format Input Display Confirm by pressing Set the key to PRG The system options are entered as 2 or 3 digits The input is confirmed by pressing c 40 40 c Note The standard settings appe...

Страница 10: ...Total is deleted after Z1 financial report printout 0 Grand Total is not printed on the financial report 17 1 Grand Total is printed on the financial report 0 Calculator mode 18 1 Journal mode 0 Basi...

Страница 11: ...ed Conclude receipt p PPPPPPP q Foreign currency payment When all the PLUs have been registered press the p key to display and print the subtotal Enter the foreign currency identification and press k...

Страница 12: ...rices which have already been concluded can be reverted d Refund function is activated Complete the registration to be reverted Conclude with q Other functions m Cash register is opened e For cash pay...

Страница 13: ...0 CH 001 20 00 RA 001 20 00 PO 51 13 1 002 300 00 CA 400 00 13 45 009 Date Z1 counter 3 digit Number of registrations in department 1 Sales for department 1 Number of registrations in department 2 Sal...

Страница 14: ...he 4 digit password press n SEC CODE A password has been programmed for the clerk Enter the clerk number Then enter the 3 digit password Conclude by pressing R What to do if the cash register does not...

Страница 15: ...ug Check whether the paper roll is inserted correctly or there is a foreign body in the printer mechanism Remove it if present Caution Remove the foreign body very carefully Do not use a knife screwdr...

Отзывы: