olympia electronics POWER LIGHT Series Скачать руководство пользователя страница 1

Thank  you  for  purchasing  this  product  of 
Olympia Electronics. A European manufacturer.

GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

where  emergency  light  is  needed.  Each 
luminaire  must  be  permanently  connected  to 
mains  power  supply

In  normal  operation  the 

power

  indicator  lights  and  the 

charge

  indicator 

blinks to show that the batteries are in charging 
condition. In  case  of  a  mains  power  supply 
failure    the   

power 

and  the 

charge

  indicators 

turns  off  and  the  luminaire    will    light  the  spot 
lamps automatically in emergency mode.  When 
the    mains    power    supply    is    restored  the 
device turns to normal operation.

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions 

ο

n page 2.

OPERATION

When  the  device  is  powered  from  the  mains

,

 

th

e

 

charge

 

indicator 

blinks  and 

confirms 

the 

charg

ing  of

  the  batter

ies

When  the  batteries 

are  charged,  it  lights  constantly. 

If 

it  does 

not 

li

gh

t, probably, the batter

ies are

 disconnected. If 

it  does 

not  li

gh

t  and  the  batter

ies

 

are

 

connected, then contact the technician. 

As long 

as  the  charge  indicator  blinks,  the  batteries  of 
the  luminaire  are  charging  and  in  this  period, 
any  autonomy  test  must  be  avoided.  When  the 
charging  circle  is  complete,  the  indicator  lights 
continuously (it can be used as an indication of 
a  power  interruption). The  batteries  charging  is 
done  by  a  3  stages  technological  advanced 
procedure,  to  ensure  the  appropriate  and  full 
charging of the batteries. 

The

 power

 indicator 

confirms 

the 

proper connection to the 

mains

. The

 

TEST

 

butto

n,  has  a  dual  use.  If  pressed 

instantlly 

while  the  device  is 

connected  to  the 

mains

the 

device 

simulates 

the 

power 

interruption

by 

lighting 

the 

lamps  for 

3

''.  In  this 

way

,

  we  can  control  the  driver  circuit  of 

the 

lamps

 and

 the

 lamps as indicated in paragraph 

3

 

in 

the text

 

below.

Dimming option

When  the  voltage  is  interrupted,  with 
corresponding  press

ing

s  of  the  button,

 

we  ca

n

 

choose 

the  illumination  of  100%,  50%,  33% 

  or 

turned off

, either to increase the autonomy time or 

not to consume 

the 

battery power unnecessarily. 

This  option  is  canceled  when  the  network  is 
restored.

ΑΤΤΕΝΤΙΟΝ

!!!

1.  Operations  for  installation,  maintainance  or 
testing  must  be  done  by  authorized  personel 
only

.

2. 

The  device  must  be  connected  to  the  mains 

power supply thru a fuse dependent by the total 
amount of the line’s  power load

.

3. 

It  is  sugested  to  check  every  month  the 

indication  LED  for  battery  charging,  and  by 
pushing  instantly  the  TEST  button  to  check  the 
emergency cirquit and the lamps. If the luminaire 
does not light 

4. 

It  is  sugested  to  check  every  6  months  the 

minimum  autononous  duration  by  disconnecting 
the mains power supply

Count the time that  the 

lamps  light  and  in  case  of  less  time  than  the 
minimum  autonomous  duration  the  batteries 
must  be  replaced.  If  the  measured  time  is 
considerably less than the minimum autonomous 

contact the installer.

 

Page

 1

 from

 2

``POWER LIGHT`` SERIES FOR NON-MAINTAINED EMERGENCY LUMINAIRES

923029009_09_005

Bayblend FR3010

transparent 

 

polycarbonate

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERY

 (

Pb

)

CHARGING TIME

INDICATIONS 

CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

EMERGENCY ILLUMINATION

LIGHT SOURCE

<24h

Power indicator, battery charge indicator, TEST button

From overcharge and deep discharge

IP 42

0 to 40  C

o

Up to 95% 

3 years 

(1 

year for the battery

)

  White power LEDs

  White LEDs

  White LEDs

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

302x94x330mm

GRL-2

1

GRL-2

1

/H/90 GRL-2

1

/H/180

GRL-29

220-240V AC/50-60Hz

90 min

180 min

6V/4Ah

12V/7Ah

12V/7Ah

2x12V/7Ah

  660lm 

  

200

0lm 

  

1

260lm 

3.

5

W / 10VA

12W / 16VA

1965gr.

6300gr.

35

60gr.

4100gr.

High Quality European based Manufacturers

Отзывы: