ELECTRICAL CONNECTIONS (after the mains interruption)
1
2
3
4
5
6
7
Unfasten the two side cover screws and remove the
plastic cap by sliding it gently.
Install the gaskets and make holes at the center of
each gasket by using a small screwdriver. Pass the
round cable through the gaskets.
Pass the communication cables through the holes
and connect them as shown in the picture when there
are other luminaires to be connected to the line
(minding the correct polarity).
If the luminaire you installed is the last one connect
the cable to one of the two inputs, as shown on the
picture (minding the correct polarity).
Address the device though the dipswitch according
to the table on page 5.
Replace the removed parts in the previous steps.
SURFACE MOUNTING ON A WALL (single sided)
Install the included plastic bracket on the wall (figure
1). Remove the aluminum bracket from the luminaire
and use the two supplied mounting screws to install
the aluminum bracket to the plastic bracket (figure 2).
Slide the luminaire to the aluminum bracket and use
the bolt on the center (*), to stabilize the luminaire
(figure 2).
CEILING MOUNTING (double sided)
Remove the aluminum bracket from the luminaire and
install it with the included spacers, screws and plugs in
the ceiling (page 3). Slide the luminaire to the
aluminum bracket and use the bolt on the center (*), to
stabilize the luminaire (figure 4).
Power on the device at the end of the installation (see
GR-8600 manual)
.
INSTALLATION INSTRUCTIONS
(*)
First, hand tighten it and then,
use pliers to tighten it little bit
more (not all the way).
Page 2 from
5
1
2
3
+L -L
4
+L
-L
Cable
entry
Screws
9230
26
00
5
_09_00
1
8
9