background image

923

060000

_09_01

7

Page

 

2 from

 

3

Release  the  push  button  and  wait.  In  a  few 
second the leds will go OFF and the light level 
setting  is  stored  in  the  memory.  If  the  push 
button  is  pressed  again  to  turn  ON  the  leds, 
the  leds  will  light  with  the  light  intensity  that 
was selected. The same can be done with the 
unit  on  it’s  charging  base.  This  way  we  can 
have  a  different  light  level  when  the  unit  is  on 
it’s  charging  base  and  a  different  light  level 
when the units is not on the base

 

(or during a 

power  failure)

The  light  level  decreases  from 

the highest level to the lowest level. In order to 
increase  the  light  level,  release  and  push  the 
button  again.  Once  the  desired  light  level  has 
been reached, release the push button and the 
current setting will be stored into memory after 
3  seconds.

 

This  setting  is  retained  into 

memory until a new setting is stored.

Battery duration and operation

When  the  unit  is  removed  from  its  base,  the 
charging  stops  and  the  unit  automatically 
enters the backup operation. Observe that the 
illumination  is  automatically  increased  to  the 
maximum  level.  To  decrease  the  light  level, 
press  the  push  button  continuously  until  the 
desired level has been reached. By decreasing 
the  light  level,  the  autonomous  duration  is 
increased.  Each  time  the  unit  enters  backup 
operation, the illumination level is automatically 
set  to  maximum.

 

If  the  unit  is  in  backup 

operation  for  a  time  period  that  exceeds  the 
above mentioned times, then the LEDs will go 
OFF  in  order  to  protect  the  battery  from  deep 
discharge.  In  this  state  the  unit  is  completely 
inoperative  and  a  complete  24  hour  charge  is 
required  until its next use.

Photo-sensor activation - deactivation

 

By  default  the  photo-sensor  is  deactivated. 
This  means  that  the  unit  will  light  if  it  is  in  the 
ON state.

 

If the photo-sensor is activated then 

the  unit  will  light  only  in  the  dark  and  if  it  is  in 
the  ON  state.  To  activate  or  to  deactivate  the 
photo-sensor  follow  the  same  procedure  as 
mentioned below:
Remove  the  unit  from  the  charging  base. 
Press  the  push  button  so  the  white  LEDs 
turned  OFF.  Release  the  button  and  press 
again continuously. In 2 seconds the LEDs will 
light.  Continue  pressing  the  push  button  for  6 
more seconds until the LEDs blink briefly. If the 
photo-sensor  function  was  disabled  then  with 
this  procedure  it  will  be  enabled.  The  same 
procedure  is  used  to disable  the  photo-sensor 
function.

Mounting on the wall

There  are  two  notches  on  the  charging  base 
which  are  used  to  pass  the  mounting  screws 
(figure 2).

Attention

- The luminaire is suitable for indoor use.
-  When  placing  the  unit  on  the  charging  base, 
ensure that the charging LED lights.
- If the unit is not used for long periods of time, 
leave  it  on  the  charging  base  in  order  to  keep 
the batteries charged.
-  Do  not  mount  the  unit  at  a  distance  of  less 
than 50 cm from a wall corner in order to avoid 
photo-sensor disturbances.
-  When  placing  the  unit  on  the  charging  base, 
align  the  pins  of  the  unit  to  the  respective  pins 
on  the  base  and  press  gently.  Do  not  exert 
excess force. 

Replaced batteries must not be thrown into 

trash  bins.  They  must  be  returned  to 
special  battery  disposal  points.  Do  not 
incinerate.

-  When  the  mains  cable  is  damaged,  this  must 
be replaced by our SERVICE department or by 
an authorized technician.

NOTE!!
After  finishing  the  installation  you  must 
power the luminaire at least for 24 hours for 
battery  charging  to  perform  the  nominal 
autonomy.

If the autonomous duration time is considerably 
less than nominal, the battery must be replaced 
with a new one with the same type.

Battery replacement procedure 

(

figure

 3).

1. 

Detach the luminaire from its base figure

 1.

2

.

 

Unfasten  the 

2

  mounting  screws  of  the  rear 

plastic and remove it

.

3. 

Remove the battery an place a new one with 

the  same  type  and  connect  it  as  shown  in  the 
picture

.

4. 

Refit the rear plastic and fasten the removed 

screws in step 1

.

Отзывы: