background image

Thank  you  for  purchasing  this  product  of 
O l y m p i a   E l e c t r o n i c s .   A   E u r o p e a n  
manufacturer.

GENERAL

These luminaires are suitable for marine and 
offshore  applications  where  emergency  light 
i s   n e e d e d .   E a c h   l u m i n a i r e   m u s t   b e  
permanently  connected  to  mains  power 
supply. In normal operation the led strip lights 
and  the  battery  is  charging.  In  case  of  a 
mains power supply failure  the luminaire will 
light the led strip  automatically in emergency 
mode.  When  the    mains    power    supply    is   
restored the device turns to normal operation.
 

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions on page 4.

Battery Charging

The battery charging is completely controled. 
In  this  case,  is  achieved  the  perfect    battery 
maintenance , as well as the elongation of its 
duration.  When  the  battery  has  completely 
charged,  it  charges  with  a  maintenance 
current.

Battery Cut-off

The  luminaire  enters  in  this  operation  when 
the mains power supply fails and battery has 
lost  its  energy.  During  this  operation  the 
luminaire enters the idle state and battery 

consumption  is  negligible,  in  order  to  be 
protected from deep discharge.

Manual Test

The  manual  test  can  be  conducted  only  if  the 
main  power  supply  and  the  battery  is 
connected.  By  pressing  the  test  button  briefly 
an  operation  test  is  initiated.  During  this  test 
period all indication LEDs are OFF.

Automatic Test

This  test  includes  all  the  operations  that 
provide  the  manual  test  and  is  conducted 
automatically  every  15  days.  In  order  to  be 
performed,  the  main  power  supply  and  the 
battery should be connected. 

Automatic Autonomous Test

The Automatic Autonomous Test  is  conducted 
and  measures  the  luminaire`s  back  up 
operation. This test is conducted automatically 
every  six  months.  In  order  to  be  performed, 
the main power supply and the battery should 
be connected (the battery should be charged). 
If  the  battery  is  not  charged,  the  test  is 
postponed  until  the  battery  is  completely 
charged.  If  during  the  Automatic  Autonomous 
Test  the  luminaire’s  duration  is  lower  than  the 
nominal, then the battery must be replaced. 

Back Up Operation

The  autonomous  duration  of  battery  during 
emergency mode is at least the one that is 

923427002_09_002

Page 1 from 4

High Quality European based Manufacturers

GR-427/12L/MAR

  SELF TESTING MAINTAINED EMERGENCY LUMINAIRE

220-240V AC/50-60Hz

Bayblend FR3010, transparent  polycarbonate

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERY (Ni-Cd)

CHARGING TIME

INDICATIONS - CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

ILLUMINATION (230V / EMERGENCY)

ILLUMINATION SOURCE 

480 min

24h

Charge, lamp fault, fault indication LED, TEST button

From overcharge and full discharge

IP 42

  12 white LED’s 

5 to 40  C

o

Up to 95% 

3 years (1 year for the battery)

272 x 121 x 50 mm

600gr.

  85/85lm 

3.6V/3Ah

3.5W / 7VA

EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3, IEC 60092-306, IEC 60533

Отзывы: