olympia electronics BSR-8020/WP Скачать руководство пользователя страница 5

Page

 

5 from

 9

125

126

127

1

1

1

1

1

1

1

ON

ON

ON

ON

ON

ON

ON

2

2

2

2

2

2

2

3

3

3

3

3

3

3

4

4

4

4

4

4

4

5

5

5

5

5

5

5

6

6

6

6

6

6

6

7

7

7

7

7

7

7

8

8

8

8

8

8

8

121

122

123

124

Address

Dip-switch

setting

Address

Dip-switch

setting

Connecting  a  BSR-80

20

/WP  to  a  BS-1636  panel

.

  ALARM  and

 

FAULT  RELAYS  are 

used

According  to  this  connection,  when  the  panel  detects  a  fault,  the  BSR-80

20

/WP 

will  send  a  fault  signal  to  the  central  panel  and  when  the

 

BS-1636  detects  alarm  on  a 

zone, the BSR-80

20

/WP will send an alarm signal.

BS-

1

636

 terminals

Loop

Connecting  a  BSR-8020/WP  with  an  isolation  lock.  When  the  lock  is  activated  (short 
circuit), the output of the device does not operate and the message 

 

DISABLE

MENT 

 

is  shown  on  the  panel

The  dip-switch

  8

  of  the

  BSR-8020

/WP  must  be  in  the  ON 

position

It can be used in a fire extinguishing system.

10k

Ω

Operation as an Input/Output unit

Operation as an Input/Output unit

56k

Ω

Loop

Operation

Dip-switch setting

1

1

ON

ON

2

2

3

3

4

4

5

5

6

6

7

7

8 9 10

8 9 10

Operate with independent

programmable 

input and output

Operate with a controller

output by the input

(

Extinguishing function)

Connecting with a flow switch

+24V

 IN

NO

+IN

C

-IN

NC

ON

OFF

+L+L+L

-L

PE

PE

+L+L+L

-L

+24V

 IN

NO

+IN

C

-IN

NC

ON

OFF

+L

+L

+L

-L

PE

PE

+L

+L

+L

-L

Connection with a conventional panel

56k

Ω

NC

NC

C

C

N0

N0

10k

Ω

ALARM

F

AUL

T

921802002_09_005

Содержание BSR-8020/WP

Страница 1: ...lity to send to the panel with a suitable connection three states quiescent fault alarm 6 Reinstall the front cover and fasten the screws that were removed in step 1 The output unit contains a fully p...

Страница 2: ...which blinks periodically in the quiescent state is a power and good operation indication On the panel the input unit is shown as INPUT OUTPUT UNIT where is the set address of the device In this func...

Страница 3: ...On the 24V IN terminal you can connect an external power supply if the function conventional detector driving unit with external power supply is selected Indication LED Blinks periodically in quiescen...

Страница 4: ...3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4...

Страница 5: ...th an isolation lock When the lock is activated short circuit the output of the device does not operate and the message DISABLEMENT is shown on the panel The dip switch 8 of the BSR 8020 WP must be in...

Страница 6: ...wer supply from panel 56k 10k Loop Loop Operate as a Input unit Operation Dip switch setting Relay is activated for 5 seconds after a reset 1 ON 2 3 4 5 6 7 8 9 10 1 ON 2 3 4 5 6 7 8 9 10 The relay is...

Страница 7: ...24V IN NO IN C IN NC ON OFF L L L L PE PE L L L L Connecting a BSR 8020 WP with conventional detectors A 10k terminal resistor must be connected on the last detector The maximum number of detectors p...

Страница 8: ...stalled on the last detector The maximum number of detectors per device is 40 conventional detectors of olympia electronics According to EN 54 the maximum number of detectors per zone is 32 devices Th...

Страница 9: ...be returned to the premises of our company for repair or replacement as long as the warranty period is valid 72nd km O N R Thessaloniki Katerini WARRANTY HEAD OFFICE www olympia electronics com Olympi...