Installation procedure

Installation procedure

940818000

_09_00

4

POWER

BURNER

BOILER

Fig

. 1

Fig

. 2

Fig

. 3

N

L

230V~

Burner

Boiler
(BS-819/R)

Fig

. 5

A

B

Fig

. 4

Programming button

 

ΒΤ1

POWER/STATUS
indicator

Burner indicator

Boiler indicator

To install the devices BS-818/T or BS-819/T

insert a flat blade screwdriver in the slot as 

shown in Figure1. 
Press and lift the front cover. Remove the retaining screws and remove the plastic cover that 
contains the keys (Fig

.2).

Use the supplied mount accessories to mount the unit according to the diagram of page 10.
Install the base, align it using the built in vial and tighten the screw to secure it.
Reinstall the plastic containing the keypad with care and fasten the screws. with a maximum 
torque of 

0,5 

Nm. 

To activate the device, remove the battery separation tape

 (

Fig

.3).

Install the front cover with slight pressure and the device is ready to operate

.

To install the BS-818/R

 

or

 

BS-819/R

remove the 4 screws of 

the front cover

 (

Fig

.4) 

and remove the cover

.

Mark and drill the mounting holes according to page 10. 
Mount the device using the supplied mounting accessories 
(Holes  A and B)  as shown in Fig.5
Do the electrical connections according to Figure 5.
Connect the phase to the L terminal and the neutral to the N 
terminal, this is used to power the device. The phase cable for 
the outputs is to the common of the relay contacts. In every 
activation, the contacts will provide the phase to the burner. 
Avoid installing the phase internally (from the L terminal to the 
relay common terminals) because it might cause interferences

 

The outputs are not fuse protected so any short circuit will 
destroy them and the device.

Содержание BS-818/KIT

Страница 1: ... BS 819 R Thank you for your trust in our products Olympia Electronics European manufacturer 8 7 6 5 4 3 2 1 CONTROL AND INDICATOR DESCRIPTION Thermostat activation Thermostat deactivation Increase value Decrease value Presence indicator Thermostat active Thermostat inactive Battery state indicator Ascending or descending temperature indicator When the selection is less than the actual temperature...

Страница 2: ...creen messages page 6 Daily programming example page 7 Weekly programming example page 8 Wireless communication settings page 8 communication errors page 9 Hour and message display Temperature and message display Temperature units display Active burner output display Selecting on not the area presence program Escape from a selection Activate Deactivate boiler valid only for the BS 819 T Go to the ...

Страница 3: ...imultaneously for 3 first the key and then the the screen will show the message and the keypad is locked Page 3 from 11 GENERAL When the plastic battery separator is remove the unit is automatically activated and shows all the screen indicators for 1 then the firmware version is shown and finally the screen enters final operation status In the center of the screen we can see the current temperatur...

Страница 4: ...nce the end time is the start time of the next program For example if we require a temperature of 23 0 ºC from 14 00 to18 00 in program 1 we will set the start time 14 00 at 23 0 ºC and the start time of the second program 18 00 with the required temperature The 24 hour time base starts at 00 00 and ends at 23 59 The start time of the next program must also be bigger than the start time of the pre...

Страница 5: ... With this setting we can turn off the screen illumination in order to conserve battery energy If ΟΝ is selected then the screen illumination will be activated every time a key is pressed If is selected then the screen illumination will be deactivated The factory default is D LED BURNER OUTPUT INDICATOR This setting can deactivate the burner output indicator in order to conserve battery energy If ...

Страница 6: ...perate The battery life time has been design to be approximately 2 years Factors that influence the battery life are prolong use of the keyboard with the backlight active increased temperature and humidity as well as battery quality 12 ANTI ICE PROTECTION If the room temperature in which the thermostat is installed falls below 5 C the unit activates the burner output irrelevant of the ON or OFF st...

Страница 7: ... blinking 4 Press the key and the starts to blink With the keys and we select the operation mode Day daily program 5 Press the key and we return to the previous screen with the blinking 6 Press the key 8 times and the screen shows with the blinking Now we are in the daily programming sub menu that has a 10 program capability 7 Press the key and the screen shows with the blinking this shows that we...

Страница 8: ...the key The weekly program will start to execute as defined In order for the program to execute correctly make sure you have programmed the device clock with the correct time WIRELESS CONNECTION SETTING This procedure is required for every new installation in order to establish the communication and to verify the quality of the signal After installing the peripheral received BS 818 R or BS 819 R t...

Страница 9: ...e interruption of the mains voltage causes the interruption of communication between the two devices When the voltage is restored the peripheral device receiver activates the outputs according to the state before the interruption until the communication is automatically restored with the thermostat maximum delay of 6 minutes so the outputs will change according to the new commands that will be giv...

Страница 10: ...a maximum torque of 0 5 Nm To activate the device remove the battery separation tape Fig 3 Install the front cover with slight pressure and the device is ready to operate To install the BS 818 R or BS 819 R remove the 4 screws of the front cover Fig 4 and remove the cover Mark and drill the mounting holes according to page 10 Mount the device using the supplied mounting accessories Holes A and B a...

Страница 11: ...r not charge the buyer depending on the reason of defection Olympia Electronics reserves the right to charge or not the buyer the transportation cost HEAD OFFICE 72nd km O N R Thessaloniki Katerini P C 60300 P O Box 06 Εginio Pierias Greece www olympia electronics gr info olympia electronics gr TECHNICAL CHARACTERISTICS BATTERIES 2 Alkaline ΑΑ BS 818 T BS 819 T BS 819 R BS 818 R MODEL 220 240V AC ...

Отзывы: