Page 15 from 18
MAIN MENU
TECHNICAL ACCESS CODE 1111
PROGRAMMING
MENU
SETUP
MENU
TEST
MENU
0
Does not communicate
1
(default) operates as central keyboard (master) (U1)
2
operates as repeater keyboard (U2)
3
operates as repeater keyboard (U3)
4
operates as repeater keyboard (U4)
0
Resetting cannot be done
1
(default) the CLEAR key resets only one call
while the code 0000 clears all the calls.
2
The CLEAR key resets only one call while
the code 0000 has no affect
3
The code 0000 resets only one call while
the CLEAR key has no affect
4
The CLEAR key resets all the calls
5
The code resets all the calls
Change the technical code
Change the user code
Recognize units which are connected with the central keyboard (Master)
Update information on the repeater keyboards from the
main keyboard (master).
Resetting all options on the keyboard to default settings.
INDICATION
INDICATION
INDICATION
INDICATION
BS-746. TECHNICAL MENU
FLOW CHART - COMMAND MENU FOR EASY AND FAST INSTALLATION .
0
B
uzzer deactivated - Signal numerator panel operation mode
1
(default) 5 shorts sounds -
2
1 long sound - Signal numerator panel operation mode
3
3 endured sounds - Signal numerator panel operation mode
4
Buzzer deactivated - Presence indication mode
Signal numerator panel operation mode
921746000_09_003