Page 13 from 18
7.5. Resetting/cancelling all calls using the user code.
In order to be able to cancel all the calls using the user code we must enable this
operation. To reset all calls using the user code simply insert the user code (e.g. 0000).
In this case all the calls will be canceled simultaneously .
7.6. Reading faults and keyboard software versions.
With
F1
key we can see any communications errors that might have occurred as well
as the keyboards software version. If we have more than one communication faults then
we can view them one by one using the arrow keys.
7.7. Fault indicator LED.
If the
FAULT
indication LED should happen to light then this would mean that we had a
communication error and that the system is not operating normally. In this case we must
call the technician that installed the system.
8. PRESENCE INDICATION MODE.
This mode of operation is used to detect the presence of people in a room-zone after
the required programming has been done.
To use this mode we must connect a terminal in each room. This can be done using for
example a room activation switch that has a volt-free relay contact. This contact is then
connected to the zone of the panel.
To program the rooms follow the directions in section
.6.1.
If we want to correspond
the rooms with alias names or numbers (e.i. Zone 1 has a corresponding alias room
number 101).
In order for the system to operate in this mode it is mandatory for us to program the
keyboard to operate with
buzz 4 mode
as described in section
6.2.3.
After the above programming procedures are finished the system is ready to operate in
presence detection mode. Each time a person is in a room and has activated the room
using his activation card his presence in shown in the form of a room number on the
display of the keyboard. If more than one rooms are activated then they are shown
sequentially in the display.
The user also has the option of scrolling through the rooms using the arrow keys.
He can also press the
ENTER
key, type in the required room number and see the
status of a room.
If it is activated it will show
(FULL).
If it is deactivated it will show
(EMPTY).
921746000_09_003