background image

www.olympia-electronics.gr

S A A R 

R T 

C E 

CERTIFICATE 

VALID SYSTEM

EN ISO 9001 : 2008

Содержание BS-746

Страница 1: ...www olympia electronics gr SA A R RT CE CERTIFICATE VALID SYSTEM EN ISO 9001 2008 ...

Страница 2: ...od 6 2 5 Ccod 6 2 6 UsuP 6 2 7 dLoA 6 2 8 r AL 6 3 TEST 7 SIGNAL NUMERATOR PANEL OPERATION MODE OPERATING 7 1 Start position operation 7 2 Calling from one call point 7 3 Calling from more than one call points 7 4 Resetting indications calls 7 5 Resetting all the calls with a code 7 6 Viewing the communication faults and the software version of the keyboard 7 7 Fault indication signals 8 PRESENCE ...

Страница 3: ...48 zones rooms To monitor 48 zones rooms we must use a BS 746 keyboard and a BS 748 panel 48 zones These 2 devices are connected to each other with four 4 wires fig 1 3 2 Systems from 49 to 240 zones rooms If we want to expand the zones rooms from 49 to 240 we have to increase the number of the panels according to the zones rooms that we want to cover For each 48 zones we must use an extra BS 748 ...

Страница 4: ...48 slave BS 748 slave BS 748 slave BS 746 address 5 address 6 address 7 address 8 address 9 A A A A A A A A A A A A Fig2 Connections shematic diagram with one keyboard BS 746 and 5 panels BS 748 signal numerator panel 48 240 zones 921746000_09_003 ...

Страница 5: ...address 7 BS 748 slave address 8 BS 748 slave address 9 Fig3 Connection diagram with4 keyboards BS 746 and 5 panels BS 748 for a complete enumerator panel system BS 746 slave address 2 BS 746 slave address 3 BS 746 slave address 4 A A A A A A A A A A A A A A A Page 5 from 18 921746000_09_003 ...

Страница 6: ...d software version 4 5 The Up and Down arrow keys ALARM EVENTS FAULT EVENTS show us the inputs which have been activated Also with these keys we can scroll through the menus 4 6 The ON OFF BUZZER HELP key is used to eliminate reset individual calls INDICATORS 4 7 The POWER LED is lighted when the panel is supplied with 230V AC 4 8 The ERROR LED is lighted when there is fault in the communications ...

Страница 7: ...the ENTER key again and the indication 1 appears this is the preset name which will appear on the Display every time that someone calls us from the zone room 1 If we want to change the name of the room we have to type the number which we want to appear e g 101 and press the ENTER key to confirm the process The Display shows the indication P 2 which is the next number of the memory second terminal ...

Страница 8: ... using the FAULT EVENTS key scroll to the menu item S UP and press ENTER The indication Clr Is shown on the display Press the ENTER key and the indication _ _ _ 1 is shown This means that this keyboard has a value of 1 Depending on this value the calls are reset cancelled as shown in the table below If we want to change the value press the required number 0 to 5 and then press ENTER so the keyboar...

Страница 9: ...e key FAULT EVENTS scroll to the indication S UP press the ENTER key and scroll to the indication buzz using the arrow keys Then press the ENTER key and the display shows the indication _ _ _ 1 This means that the buzzers sound mode is 1 The table below explains the different sound mode that are available VALUE PROGRAMMING Buzzer deactivated Signal numerator panel operation mode default 5 short so...

Страница 10: ...oard Master This programming operation recognizes all the peripheral devices panels repeater keyboards which are connected to the main keyboard Master This process is necessary and is the first step which we have to do when the panel operates for first time Insert the technical code 1111 and using the FAULT EVENTS key scroll to the indication S UP press the ENTER key and using the arrow keys scrol...

Страница 11: ...programs in sequence e g P1 P2 P3 P4 P240 At the end of the process press successively the ESC key so as to exit the programming procedure 6 2 8 r AL Clearing and resetting the keyboard to default conditions This programming operation resets all the names which have been programmed for every room and returns these values to their default settings Insert the technical code 1111 and using the FAULT ...

Страница 12: ... the programming procedure Page 12 from 18 7 SIGNALNUMERATOR PANELOPERATION MODE This operation mode is for the user and is very simple When the mounting and programming process has finished and the system has been tested and is operating then the user can do the following operations 7 1 Starting position operation The system is ready to accept the calls of the zones rooms and on the control keybo...

Страница 13: ... use this mode we must connect a terminal in each room This can be done using for example a room activation switch that has a volt free relay contact This contact is then connected to the zone of the panel To program the rooms follow the directions in section 6 1 If we want to correspond the rooms with alias names or numbers e i Zone 1 has a corresponding alias room number 101 In order for the sys...

Страница 14: ...dure This procedure last for a few minute and the display shows the units that are searched for by the keyboard in sequence U2 U3 U4 U9 If the keyboard detects a unit it will report it e i C _ _ 5 The buzzer sounds briefly and the detected unit is stored in memory After finishing the detection process press the ESC key as many time as it is required in order to exit programming mode 9 4 System che...

Страница 15: ... CLEAR key resets all the calls 5 The code resets all the calls Change the technical code Change the user code Recognize units which are connected with the central keyboard Master Update information on the repeater keyboards from the main keyboard master Resetting all options on the keyboard to default settings INDICATION INDICATION INDICATION INDICATION BS 746 TECHNICAL MENU FLOW CHART COMMAND ME...

Страница 16: ...Call point Page 16 from 18 Call point Call point Call point Call point Call point 921746000_09_003 ...

Страница 17: ...ll points that are connected to the terminal blocks 8 24 are connected in the same manner as the call points on the terminal blocks 1 7 The call points that are connected to the terminal blocks 25 43 are connected in the same manner as the call points on the terminal blocks 44 48 921746000_09_003 ...

Страница 18: ...Page 18 from 18 921746000_09_003 ...