Batteries should be protected from excessive heat, such as direct light beams or
fire.
Ÿ
Do not install the smoke alarm in direct sunlight. Keep at least 0.5m from light
sources.
Ÿ
Due to the loudness of the alarm, make sure that you always stand at arm's
length distance from the unit when you are testing.
Ÿ
Do not charge batteries
The BS-506 is a
battery operated smoke alarm with an optical sensor for installation
in residential buildings, apartments and rooms. Smoke
alarms
are designed to
provide an early warning of fire events giving enough time for people to evacuate
the building/room. Always consult local regulations for smoke alarms.
CAUTION!!
Ÿ
To prevent injury, the device must be securely attached to the ceiling in
accordance with the installation instructions.
Ÿ
Do not paint or cover the smoke alarm.
Ÿ
Consult the manufacturer's advice if the device doesn't work properly.
Ÿ
Do not install the smoke alarm close to ventilation points.
Ÿ
Do not install the smoke alarm in leisure accommodation vehicles
Ÿ
Do not mix new and used batteries or batteries of different types or brands
Ÿ
Exhausted batteries should be immediately removed from equipment and
properly disposed of
Ÿ
Do not deform batteries
Ÿ
A lithium battery with a damaged container should not be exposed to water
Ÿ
Replace all batteries of a set at the same time.
Ÿ
Clean the battery contacts and also those of the equipment prior to battery
installation
Ÿ
Ensure that the batteries are installed correctly with regard to polarity (+ and –)
Ÿ
Remove exhausted batteries promptly
DEVICE TEST
A Device Test is performed when the TEST button is pressed for more than 1
second. If the device works properly it will produce a loud alarm sound. When the
TEST button is released, the alarm sound will stop and the device enters the Hush
mode. After a time of 9 minutes returns to normal (stand by) operation.
LOW BATTERY MODE
Ÿ
Do not dismantle batteries
If the battery's level is low, the horn will sound as a short pulse every 43 seconds
which continues until the batteries are replaced. If a low battery condition exists, a
Low Battery Hush mode can be selected by pressing the TEST button, the Red LED
will turn on to indicate the low battery condition. After the TEST button is released,
the unit enters Low Battery Hush mode and the device is silenced for 8 hours. At
the end of the 8 hours, the audible indication will resume. The activation of the
TEST button will also initiate the 9 minutes Hush mode.
HUSH
When the device is in Alarm condition, every Device Test will initiate the Hush
mode. When Hush mode is started, the unit immediately resets out of Alarm
Ÿ
Store unused batteries in their original packaging away from metal objects. If
already unpacked, do not mix or jumble batteries
FAULT WARNING
ALARM MEMORY
The Alarm Memory allows easy identification of any unit that had previously been in
Alarm. When a smoke alarm exits an Alarm condition, the Yellow LED flashes three
times and this pattern repeats every 43 seconds. This visual indication will stop after
a period of 24 hours. The user will still be able to identify a unit that had previously
been in Alarm, by pressing the TEST button, the horn will sound in short pulses and
the Alarm memory resets. The initial 24 hour visual indication is not displayed when
a low battery condition exists.
When the smoke alarm is not functioning properly, it will turn into the Fault warning
mode and produces three short acoustic signals every 43 seconds. Try cleaning the
smoke alarm (see paragraph maintenance) otherwise replace it!
condition and the horn is silenced. The Hush mode duration is 9 minutes and the
Red LED flashes faster, after this period expires, the unit goes back to its normal
operation. During Hush mode, the device's sensitivity is reduced and a higher Smoke
concentration is needed, to place the unit again into an Alarm condition. Also, Hush
mode can be canceled from the user by performing a new Device Test.
—
Test the smoke alarm weekly for correct operation using the Device Test
facility. If the smoke alarm functions correctly, it will generate a loud beep
otherwise must be replaced immediately!
—
Use a vacuum cleaner with a soft brush and vacuum all sides and covers of
the smoke alarm. Do not remove the top cover of the smoke alarm to clean
it inside.
—
Clean the smoke alarm once per month to remove dirt, dust or debris.
—
Do not attempt to repair this smoke alarm. If the smoke alarm shows a
damage it must be replaced!
—
In accordance with EN14604 standard, is recommended to replace the
device after 10 years of operation.
1
2
1
1
Smoke alarm
AA Batteries (installed)
Mounting accessories
Manual
Package Contents
Maintenance
General
Installation instructions
1
2
3
1
5
6
2
3
4
6 mm
If no sound is generated, the smoke alarm is not functioning properly and
should not be used!
NOTE!!!