Programming how the passwords function
If after selecting
«CODES» and pressing (*) we select «CHANGE PASSWORD» we see:
Via this option we can select the way that each user
password functions.
We enter the number of the password that we want to
program or to change the password function and we see:
For each code we must make one of the following selections
which mean:
«OFF». The password is present but does not have any
function.
«NATURAL ARM DISARM.». The password arms and disarms
the panel. Making this selection by pressing the (*) we must
select the section that the password affects. We select A, B, C or
ABC. By default all passwords are set for
«NATURAL ARM
DISARM» and for section ABC.
“PANIC 24 HOURS”. This password gives a panic alarm whichever state the panel is.
SET. The password arms (doe not disarm) the panel immediately. Making this selection and pressing
the (*) we must select the section that is affected by the password. We can select A, B, C or ABC.
UNSET. The password disarms (does not arms) the panel immediately. Making this selection and
pressing the (*) we must select the section that is affected by the password. We can select A, B, C or
ABC.
SET WITH DELAY EXTRA. The password arms only (does not disarm) the panel but with an exit
delay. Making this selection and pressing the (*) we must select the section that is affected by the
password. We can select A, B, C or ABC.
PG CONTROL. The password activates or deactivates one of the controllable outputs. Making this
selection and by pressing (*) we must select the output that the password affects. We can select
Ρ1 or
Ρ2.
SILENT ALARM. The code activates the silent alarm. When the user enters the code, the panel will
disarm (if the panel is armed) and will remain in idle state (the siren will not sound, and the alarm leds
will be off). The panel will call or send a message via BS-454 to the selected telephone numbers.
General settings
From the
«TECHNICIAN MENU» if we select «SETTINGS» we see:
From this menu we can adjust all the general settings of the panel.
«ENTRANCE TIME». This is the time that the zones delay to give an alarm. This is valid only for
zones that have been programmed as zones with delay. By pressing (*) a new screen is shown and
the current entrance delay is shown (30) in seconds. Enter the new time (05-99 2 digits are
mandatory) i.e. 0 and 9 for 9 seconds. The system stores the value and returns to the menu
«SETTINGS».
CHANGE PASSWORD
SELECT FROM 01-20
- -
__
CODE REACTION __
OFF
NATURAL ARM DISARM.
PANIC 24 HOURS
SET
UNSET
SET WITH DELAY EXTRA.
PG CONTROL
SILENT ALARM
Содержание BS-458
Страница 1: ...BS 458 Burglar alarm panel ...
Страница 30: ...8 10 2015 30 921458000_09_003 the connected devices and the keyboards are shown Press OK to continue ...
Страница 34: ...8 10 2015 34 921458000_09_003 This procedure is adhered too for every change in the settings ...
Страница 39: ...8 10 2015 39 921458000_09_003 The screen above shows a typical system ...
Страница 50: ...8 10 2015 50 921458000_09_003 ...