background image

Page

 

1 from

 

4

 

“BAU LIGHT” SERIES SELF TESTING MAINTAINED EMERGENCY LUMINARIES

Page

 4

 from 4

220-240V AC/50-60Hz

1 h / 

3

 h / 8 h manually selected (default 3h)

24 h

LED

 

Charge,

 

Battery Fault LED / Magnetic Test Contact

3.6V/

3

Ah

4

.5W / 

4

.7VA

IP

54

EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

o

5 to 40  C

up to 95% 

ABS/PC, PC

776

gr.

270lm

1 h : 350lm / 3 h : 280lm / 8 h : 90lm

30

 white LED

4

.1W / 

4

.3VA

3.6V/

1

.

5

Ah

1

 h : 300lm / 3 h : 150lm / 8 h : 30lm

745

gr.

845

gr.

816

gr.

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT
GUARANTEE 

OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERY  

(

Ni-Cd

)

CHARGING TIME

INDICATIONS 

CONTROLS

MINIMUM AUTONOMY DURATION

DEGREES OF COVER PROTECTION

LUMINOUS FLUX (emergency)

PRODUCED IN ACCORDANCE WITH

LUMINOUS FLUX (230V AC)

VEWING DISTANCE

ILLUMINATION SOURCE 

GENERAL

o

These  luminaires  are  used  indoors 

(

ta  40 C

)

 

where emergency light is needed.
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected  to  mains  power  supply

.

  In  normal 

operation  the  illumination  LEDs  are  lit  as  well 
as the green indicating charge LEDs when the 
battery  is  charging.  In  case  of  a  mains  power 
supply  failure,  the  luminaire    enters  in 
emergency  mode  and  will  light  automatically. 
When  the  mains  power  supply  is  restored  the 
device turns to normal operation.

AUTONOMY DURATION SELECTION

The  user  can  select  one  of  the  3  available 
minimum  autonomy  durations  1  hour,  3  hours 
and  8  hours.  The  procedure  of  autonomy 
selection is   described on page 2.

TECHNICAL LABEL INSTALLATION

Two  additional  labels  are  included  in  the 
package. One for 1 hour duration (60) and one 
for  8  hour  duration  (480).  Depending  on  the 
selected duration, the installer must replace the 
default 3 hour (180) label with one that has the 
required  duration.  Please  take  notice  of  the 
orientation of the label.

INSTALLATION

To  install  the  luminaire  follow  the  installation 

instructions on page 3.

Battery Charging

The battery charging procedure is controlled by 
the processor, this maintaining its best possible 
preservation, as it extends its duration.

Battery Cut-off

The luminaire enters this mode when the mains 
power  supply  fails

 

and  battery  has  lost  all  its 

energy

During  this  operation  the  luminaire 

enters the idle state

 

and battery consumption is 

negligible,  in  order  to  be  protected  from  deep 
discharge.

Manual

 Test

This test can be done 

by using the

 

A-1900 card

 

as  described  on  page 

2

.

  The  light  source  and 

the  emergency  circuit  of  the  device  are  tested. 
The  manual  test  can  be  conducted  only  if  the 
mains  power  supply  and  the  battery  are 
connected. This test lasts for 3 seconds.

Automatic Operational Test

This  test  includes  all  the  operations  of  the 
manual  test  and  is  conducted  automatically 
every  15  days.  In  order  to  be  performed,  the 
mains  power  supply  and  the  battery  should  be 
connected. This test lasts for 3 seconds.

Thank you for your trust in our products  

Olympia Electronics - European manufacturer

3 years 

(1 

year for the battery

)

TECHNICAL CHARACTERISTICS

 

(for LED MODULE specifications see page 4)

Battery replacement

It can be done only by a competent person and after the mains supply interruption

.

1. 

Dismantle the device

 

(step 1 and step 2 of

 the installation 

instructions)

.

2. Disconnect the connector and remove the old battery.
3. Connect the new battery with the same type (step 

6

 of the installation 

instructions

) and

    place it in the position of the old one.
4. Follow the step 

7

 of the installation procedure and power the device. 

(*)

 

Maintained  operation:  The  luminaire  lights  its  illumination  source,  when  it  is  powered  by 

the mains power supply or not

Non Maintained operation: The luminaire lights its illumination source,

 

only in   power supply’s 

failure.

NOTE: 

LED= Light Emitting Diode

LABELING EXPLANATION:
X: 

Self contained 

  

1: 

Maintained 

(*)

A: 

Including test device

F: 

Automatic test gear complying

    with IEC 61347-2-7 denoted EL-T

G: 

Internally illuminated

60:

 1 hour duration 

 

180: 

3 hours duration

480:

 8 hours duration

The light source contained in this luminaire shall only be replaced by the manufacturer, or his 

agent, or a similar qualified person.

NOTE! The light source is non-user replaceable.

WARRANTY

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty 
is  specified  in  the  official  catalogue  of  Olympia  Electronics  and  also  in  the  technical  leaflet,  which 
accompanies  each  product. This  warranty  ceases  to  exist  if  the  buyer  does  not  follow  the  technical 
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods 
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully 
agreed to them in writing. 

Products that have been damaged can be returned to the premises of our 

company for repair or replacement, as long as the warranty period is valid.

Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the 
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the 
buyer the transportation cost.

HEAD OFFICE

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P.C. 60300 P.O. Box 06 Εginio Pierias Greece

www.olympia-electronics.gr
[email protected]

LED MODULE CHARACTERISTICS

Manufacturer

Model Number
Voltage Range

Connections

Nominal Power

Temperature (tc)

Olympia Electronics S.A

45 °C max. across the board

Non-reversible connection between main pcb and led module

13-14VDC

13-13.6VDC

2W max

1.5W max

2505195

GR-750/ST/HP/LL GR-751/ST/LP/LL

GR-752/ST/HP/HL GR-753/ST/LP/HL

X

1

A

F

1 8 0

G

358 x 85 x 88 mm

358 x 125 x 88 mm 358 x 85 x 88 mm 358 x 125 x 88 mm

*15m, **17m

15m 

15m 

*15m, **17m

NOTE!!

 The installer should fill in, on the specification 

label, the letter 

G

 if the luminaire is used as a safety sign.

GR-750/ST/HP/LL

GR-751/ST/LP/LL GR-752/ST/HP/HL GR-753/ST/LP/HL

923

753000_09_00

4

923

753000_09_00

4