3
Press button 4x
= Programme 4 „Backflex“:
> stretching of the lumbar vertebrae only
> control lamp „Backflex“ (H) lights up
Press button 5x
= return to programme 1
D By means of the „STOP“ button (D) you can switch off all massage programmes at any time.
(Massage unit returns to park position). During this period (approx. 15 Sec.)
the footrest
cannot be operated! To provide a comfortable exit from the wash unit for the clients, you
have to remove the footrest (B) and after that you have to switch off the massage function (D).
·
The massage function switches off automatically after 16 minutes. It can be restarted immediately
using button „Prog.“ (C).
·
The remote control is held magnetically at the holding button at the side of the backrest on the left and
the right (Fig. 8).
Important user information regarding the remote control:
The wash-basin remote control unit is designed exclusively for the use of clients with dry
hands. To guarantee correct operation of the electronic components, the remote control unit
must in no circumstances be allowed to come into contact with water, shampoo or other
fluids.
If it is operated with hands covered in foam, or with dirty hands, the remote control unit
will not operate correctly, there will be lasting damage to the electrical components, and the keys may
become permanently soiled.
The guarantee does not cover damage to the electronics as a result of the effects of wetness!
If, in exceptional circumstances, stylists need to operate the remote control themselves, it is essential that
the plastic cover be used.
3. Base
The installations and corner valves are located in the base behind the inspection cover.
Please Note:
>
We recommend to provide the supply lines with a central shut-off device.
>
If the system is operated without a suitable shut-off device, the angle valves must be closed at the
end of business hours.
a. Inspection cover (fig. 4)
·
To open, grasp the upper recess and pull to release magnetic connector, then lift out of the lower
seating.
WARNING: Always isolate the complete system and secure against unintended
switch-on before opening the inspection cover!
·
When closing the cover first align below and afterwards click back into the magnetic connector
above.
b. Care of the plastic surfaces
·
Clean the plastic surface of the base with a damp cloth or a micro-fibre cloth, if necessary with
a mild household cleaning fluid.
·
Under no circumstance use an abrasive cleaner!
·
Please ensure that spots of various hair chemical agents (above all directly applied colouring
agents) do not fall on the plastic surfaces, as these cannot be removed.