3
1.
General information
Before checking and operation, it is mandatory to carefully read the subheading ''Operator's
manual'' (7.5).
All entries in the passport are made only with ink, distinctly and accurately. Erasures, blots,
uncertified corrections are not allowed.
2.
General product information
2.1. The "X Band Up/Downconverter" is designed for round-the-clock continuous operation mode (at
least 20 hours and 4 hours break) in normal climatic conditions.
2.2. Supply of the "X Band Up/Downconverter" is carried out from the source of the single-phase
alternating current with a voltage of 220V and a frequency of 50Hz.
2.3. The "X Band Up/Downconverter" consists of one unit (Fig. 1).
The unit on the front panel has four RF inputs and three RF outputs, 1 input for the unit control,
indicators and a network switch. The back panel of the unit has a connector for the power supply,
programming port and a grounding bolt.
2.4. "X Band Up/Downconverter" meets the safety requirements of Russian State Standard for
electrical, mechanical, and fire safety - GOST R IEC 60950.
3.
Purpose of the product
This X Band Up/Downconverter is specifically designed to operate in X Band. X Band
Up/Downconverter is controlled using digital lines. When digital lines are used faster switching speed
and more reliable control can be achieved.
4.
Technical specifications
In the Table 1 are shown technical specifications of X Band Up/Downconverter.
Table 1
S.No.
Description
Specification
Downconverter Specifications
1
Input Frequency
X - Band (8 - 12 GHz)
2
Output Frequency
Fixed at 1GHz or Variable in 1 - 5GHz