background image

~

2

~

Stove Safety

When properly maintained and operated your stove should give you many years of service, however
there are important safety aspects of these products that you need to be aware of when operating a
stove.

1.

The term Multi-fuel refers to any of the main commercially available solid fuels such as coal,
wood, turf, anthracite, briquettes. Never use liquid fuels such as oil or kerosene when lighting
or refreshing the fire or at any other time. Do not store liquid fuels near stove.

2. The burning of wood gives off gases which can be extremely dangerous. The stove is designed

that under normal operating circumstances these gases pass up the flue chimney system and
cannot escape into your home, however it is important that your flue system is properly
installed and that you check all joints regularly to ensure that there are no cracks or gaps,
check the door sealing rope and replace when damaged. We recommend a smoke alarm be
fitted in rooms where stoves are installed. Do not use stove in a room where negative pressure
conditions may occur, such as through the use of extraction fans unless an adequate air supply
into the room is ensured, as this may draw air through the stove and cause products of
combustion to escape into the room.

3. Creosote and soot may accumulate in your flue pipe and chimney. This may ignite, causing a

chimney fire. If you suspect a chimney fire evacuate people from the building, close down the
air controls on the stove and call the Fire Department. To prevent the accumulation of soot or
creosote, check flue and chimney regularly and clean as necessary. Good burning, hot stoves
will generally cause a lot less build-up than slow burning stoves, likewise dry wood will cause
less build-up than wet wood. We recommend a fire extinguisher be available where stoves are
in operation. In the event of a chimney fire do not re-light the stove until it and the flue
chimney system have been thoroughly checked and repaired as necessary.

4. Stoves get extremely hot and should not be touched when lit. When young children are in the

area, we recommend the use of a suitable fire guard around the stove. Always wear protective
gloves when reloading stove.

5. Never over-fire your stove. If external parts of your stove are glowing red then the stove is

over-firing and your draught settings should be reduced. Never interfere with the draught
mechanisms or adjust your air settings outside those limits set when the stove is manufactured.
Never use a fan to supply air to the stove or to extract air from it.

6. All users of the stove should be aware of the contents of this manual. Please leave this manual

where it is accessible to stove users and do not allow anyone to use the stove that is unfamiliar
with its correct operation.

7. Never use the stove if any parts are missing or damaged, only use genuine parts as

replacements. Never modify your stove.

8. Never use a fan to supply air to the stove or to extract from it.

Содержание HF-706

Страница 1: ...t s very important that you thoroughly read and understand all instructions before using your new stove or fireplace Check Building Codes When installing operating and maintaining your stove follow th...

Страница 2: ...chimney fire evacuate people from the building close down the air controls on the stove and call the Fire Department To prevent the accumulation of soot or creosote check flue and chimney regularly an...

Страница 3: ...allow any creosote to run down the inside of the pipe and not to come out and cause an unsightly mess and possible fire hazard All joints in the flue system should be sealed with fire cement and or a...

Страница 4: ...n soft surface remove hob blanking plate from underside of hob by taking out 2 screws remove flue blanking plate from top outlet and fit to back outlet making sure it is properly sealed with ceramic r...

Страница 5: ...himney may also present problems with the chimney draw The connecting flue pipe must be sealed to the chimney with fire cement and high temperature resistant rope as required This is usually done into...

Страница 6: ...nt board TOP FLUE OUTLET If the chimney is not sound i e found to be leaking after a smoke test then the chimney must either be repaired or a flexible liner may be used ensure the liner is the correct...

Страница 7: ...e correct type for Multi Fuel applications Some typical installations are shown as following Support Collar Fire Stop Spacer Radiation Shield Fire Stop Spacer Twin Wall Flue Pipe must start at least 1...

Страница 8: ...or adjacent building whether or not beyond the boundary Note 3 At least 600mm above the adjacent building Notes 1 The weather surface is the building external surface such as its roof tiles or extern...

Страница 9: ...h kg The figure shown for wood is based on dry hardwood First operation of stove You should begin using your stove by lighting small fires which get progressively bigger We recommend a series of about...

Страница 10: ...equently Close the door gently after stove is reloaded You should always wear protective gloves and use tongs when tending a hot stove Ash removal Your stove is fitted with a shaker grate to remove th...

Страница 11: ...l bed into the stove and allow it to burn for about 15 minutes so as not to kill the fire Then close the secondary air supply at the top of the door and turn the primary air inlet to almost closed The...

Страница 12: ...replacements when the stove is cold Surface finish The stove should only be cleaned using a damp cloth Some cleaning products may leave stains on the stove surface Never use abrasive cloths as these...

Страница 13: ...have damage to the sealing Check the condition of the door sealing rope and the joints within the stove If neither of these solve the problem you may have too much draught on your chimney and you may...

Страница 14: ...vented gravity Feed Expansion Tank must rise continuously and will require a 25mm water clearance from below the warning pipe All pipe work and fittings must comply with all relevant fitting and Europ...

Страница 15: ...it automatically opens the air inlet to the set open position when the water temperature is lower than 80 3 This way the thermostat makes the water temperature not change too much WATER HEATING SYSTEM...

Страница 16: ...long period of time it is recommended to drain the system NORMAL RUNNING During normal running this condensation should be minimal if the system is fitted with a low limit thermostat This low level th...

Страница 17: ...not be damaged or missing 4 You must not have used the stove to burn any of the prohibited fuels listed 5 The stove must have been continuously kept in a serviceable condition and you must not have a...

Отзывы: