User manual
VARMARE
Problem solving
Problem
Possible cause
Solution
The device is plugged in, no
diodes are on.
Problem with the
connection.
Check the connection of the
power wire, the plug and the
socket.
Heating element is not heat
-
ing, outside diodes are blink
-
ing alternately.
Temperature sensor has
been damaged.
Disconnect the device com
-
pletely, wait until the radia
-
tor cools down and re-con
-
nect it again.
Overheating of device.
Check and confirm that the
heating element's out put
does not exceed the recom
-
mended output of your radi
-
ator. Check and reduce the
water tem perature in the
central heating system-must
not exceed 82°. In electric-
only version check, if the radi
-
ator is properly filled with the
heating agent.
The device is heating de
-
spite turning it off with the
button.
Damaged electronics.
Disconnect the device com
-
pletely, wait until the radia
-
tor cools down and re-con
-
nect it.
If the problem continues please contact Your local Distributor.
Содержание VARMARE
Страница 1: ...PL DE EN VARMARE ...
Страница 2: ...600 mm Zone 1 Strefa 1 Zone 2 Strefa 2 ...
Страница 47: ...47 DE ...
Страница 50: ...PL Grzejnik elektryczny EN Electric only Radiator DE Elektrischer Heizkörper Instalacja I Installation ...
Страница 51: ... 90 0 5 h MAX 1 2 1 2 MAX 60 1 3 5 7 2 4 6 22 230 V 50 Hz Instalacja I Installation ...
Страница 52: ...OLTENS 1 Sp z o o ul Karola Marcinkowskiego 16 63 200 Jarocin www oltens com MGKE 632 20220811 CIBTO ...