21
Instructions for the installer
Heater Positioning and Installation
•
The electrical installation of this heater must be
approved by your local electricity company.
•
The installation must be carried out by a competent
electrician.
•
Electrical installation and local safety regulations
must also be adhered to.
•
If heaters are to be installed in commercial or pub-
lic buildings such as hotels, holiday homes or
apartments, schools, administrative buildings etc.,
a special warning label is to be attached to the top
of the heater. This label is available from your local
contractor.
Procedures to be followed
All National and Local Safety Codes should be ad-
hered to both at the planning and installation stages.
Choosing the Heater Position
The heater can be positioned anywhere within the
room to be heated.
The floor and/or the wall must be able to take the
weight of the heater. Please, therefore, note carefully
the weights given in the Technical Data section of this
instruction. If in doubt, consult a building engineer or
architect.
Olsberg storage heaters generally need no protective
underboard when standing on normal flooring, as long
as this is flat and smooth and can withstand tempera-
tures of 80°C minimum.
In the case of soft, load-sensitive or non-heat-resistant
floors or carpeting, as well as to even out any sur-
faces, it is advisable to first put down a protective
board the size of the underside of the heater. When
using high- or thick-pile carpeting a protective board
should
definitely
be used.
For appliances without integral room thermostats, the
wall-mounted room thermostat should be mounted
preferably on an internal wall, at least 2.5m from the
heater and at a height of approx. 1.5m.
Assembly
The heater should be only removed from its packag-
ing near to its place of final assembly.
Small cracks or chips in the heater core bricks have
no influence on the operation of the heater.
Minimum Clearances
For reasons of safety, the following minimum clear-
ances are to be adhered to:
•
From cover and side panels ...........................10cm
•
From air-outlet grille........................................25cm
Tilting Safety, Wall Mounting
Olsberg electric storage heaters must be protected
against tipping over. To do this, the heaters are to be
fixed to the wall.
The heater should first be mounted to the wall as
shown in Fig.1 using the screw and wall-plug pro-
vided. The fixing screw can be threaded through ei-
ther the left-hand or right-hand inside panel.
Содержание 14/534
Страница 5: ...5 Fig 1 Wandbefestigung Ger t Ma H Ma A 14 534 800 674 14 536 1056 930...
Страница 11: ...11 Schaltplan 78 4514 5361...
Страница 22: ...22 Fig 1 Wall Mounting Heater Dim H Dim A 14 534 800 674 14 536 1056 930...
Страница 39: ...39 fig 1 Fixation au mur Appareil Dim H Dim A 14 534 800 674 14 536 1056 930...
Страница 56: ...56 Fig 1 Muurbevestiging Apparaat Afmeting H Afmeting A 14 534 800 674 14 536 1056 930...
Страница 62: ...62 Schakelschema 78 4514 5361...
Страница 70: ...70...
Страница 71: ...71...