3. External wiring diagrams
Power supply
Power supply circuit breaker(prepared by user)
Power supply circuit breaker
(prepared by user)
Outdoor
unit
Indoor
unit
Defrost connecting cable
Control connecting cable
Power supply connecting cable
Power supply cord
Electric heater
Power supply cord
Power supply
b. If LCD screen displays normally.
a. After checking, energize your appliance and press the buttons on the control panel
to see if the buttons function;
Function test
if the all wires and cables are correctly connected and well fixed.
b. Check if the power supply complies with requirements; if there is refrigerant leakage;
a. Check if piping, drainage and external wiring have been finished correctly.
Before testing
1. Please read this operating and installation instructions carefully.
2. Do not let air in or refrigerant out during installing or reinstalling the appliance.
3. Test run the air conditioner after finishing installation and keep the record .
4. Type of fuse for controller of indoor unit is 50T, rated specification is T 10 A, 270V.
Fuse for the whole unit is not supplied by the manufacturer, so the installer must
employ a suitable fuse or other over-current protective device for the power supply
.
circuit according to the maximum power input as required
5.The air conditioner operates safely when ambient static pressure is 0.8~1.05 standard
atmosphere pressure.
Notes
TEST RUN
20