Olmo OSH-T18HRK3 Скачать руководство пользователя страница 30

1

2

3

SWING

SLEEP

FAN

TURBO

HEALTH

SWING

TIMER

ECO

MODE

DISPLAY

Ambient temp 

Auto temp.

 20

     23

     23

 26

20

~

26

Operation mode

HEATING ( FOR HEAT PUMP TYPE)

DRY

COOL

     18

FAN  (FOR COOL ONLY  TYPE)

FEEL MODE   

SLEEP MODE   

SWING

SLEEP

FAN

TURBO

HEALTH

SWING

TIMER

ECO

MODE

DISPLAY

To activate the FEEL (automatic) mode of operation, press the  MODE   button 
on the remote control until the symbol     appears in the display. 
In the FEEL mode the fan speed and the temperature are set automatically 
according to the room temperature (tested by the probe which is incorporated in 
the indoor unit)to ensure user comfort. 

To optimize the working  of  the conditioner, adjust the temperature(only 2

 

)(1), the speed (2) and the direction of the air flow (3) by pressing the buttons 
indicated .

To activate the SLEEP mode of operation,  press the   SLEEP   button on the 
remote control until the symbol     (AUTOQUIET ) appears in the display.
The function 

SLEEP

 automatically adjusts the temperature  to  make  the  

room  more  comfortable during the night sleep .  In cooling or dry mode , the set 
temperature will automatically raise by1 

 every 60 minutes, to achieve a total 

rise of 2 

 during the first  2 hours of  work.

In  heating  mode  the  set  temperature  is  gradually decreased by 2 

 during the 

first 2 hours of work.
After 10 hours running in sleep mode the air conditioner is swicthed off  
automatically.

29

Содержание OSH-T18HRK3

Страница 1: ...OSH T18HRK3 OSH OU18HRK3 MODEL...

Страница 2: ...Y PANEL CHARGE ADDITIONAL REFRIGERANT AIR PURGING ELECTRIC WIRING TEST RUN REFRIGERANT PIPE INSTALLATION OUTDOOR UNIT INSTALLATION INSTALLATION OF PANEL PRECAUTIONS REMOTE CONTROLLER INDOOR UNIT INSTA...

Страница 3: ...fective it will cause water leakage electrical shock or fire Use the attached accessories parts and specified parts for installation Otherwise it will cause the set to fall water leakage fire or elect...

Страница 4: ...above problem happened It is advisable that the air conditioner should be given a detail check up after using for five years even if none of the above happen Do not place any obstacles in front of the...

Страница 5: ...OPERATION OF PANEL S PARTS 5 4 2 1 Infrared signal receiver Manual Switch Nixie tube Running light Timing light Defrosting preheat light warning light Buzzer 4 DISPLAY PANEL DISPLAY PANEL Infrared sig...

Страница 6: ...ne liquid evaporating h A place where air circulation is not enough I The appliance shall not be installed in the laundry 2 Electrical Insulation must be done on the air conditioner and the building c...

Страница 7: ...ng on the ceiling has been decided Confirm sizes of the indoor unit and ceiling opening with the attached installation paper pattern Please fix the paper pattern below the body with M5X16 screws 4 Ple...

Страница 8: ...cture Bolt Bolt with M10 whorl is to be used The center distance between the bolts is decided by the size of the unit Use the following method to install Installation method should be changed under th...

Страница 9: ...tallation Be sure to seal the connection parts between and the panel the indoor unit or even small gaps may cause wind water leakage or condensing water the panel the ceiling Be sure to follow Install...

Страница 10: ...about 10mm Lean Downward over 1 100 Flexible Hose Connection Procedure Core shift adjustment o Bend 45 C Maximum Hose band Flexible Hose Indoor Unit The listed material should be used Connect the tra...

Страница 11: ...rainage test is doing during checking the drain pump motor running sound Reset the water level switch connection to the original position after the drainage test Drainage Upward Drainage Test To make...

Страница 12: ...on the electrical box aligns the one on the panel 2 Please connect step motor wire display board wire to the electrical box according to ELECTRIC WIRING DIAGRAM on the electrical box 3 Then screw the...

Страница 13: ...is a risk of muddy water 6 Install it where your neighbors would not be annoyed by operating noise or discharged hot air 7 Install it on a fixed shelf that is not subject to increasing noise 8 Install...

Страница 14: ...pe but not including the drainage pipe Drainage pipe can be fixed along them separately Wrapping from the joint of outdoor unit to that of indoor unit each round of tape should cover half of its previ...

Страница 15: ...to vacuum from the gas side refrigerant adding mouth of the outdoor unit Don t use the refrigerant of the outdoor unit to do the vacuum A certain volume of refrigerant had been added into the outdoor...

Страница 16: ...frigerant volume to be added is calculated according to outdoor unit installation manual Be sure to add refrigerant measuring by a scale If the added refrigerant volume is inadequate too much or insuf...

Страница 17: ...lations The grounding wire should be away from gas pipes water pipes telephone lightening rods or other grounding wires Improper grounding may cause electric shock If the wiring capacity is not enough...

Страница 18: ...connecting 5 Grounding work must be carried out for indoor and outdoor units 6 Install the components removed back to the unit Outdoor unit Thermal insulation Materials Connecting pipes Electric contr...

Страница 19: ...here is refrigerant leakage a Check if piping drainage and external wiring have been finished correctly Before testing 1 Please read this operating and installation instructions carefully 2 Do not let...

Страница 20: ...E Before you clean the air conditioner be sure to disconnect the power supply plug CAUTIONS Use a dry cloth to wipe the indoor unit and remote controller A cloth dampened with cold water may be used o...

Страница 21: ...filter must be increased If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting 1 Open the air in grill Push the gri...

Страница 22: ...y while the air conditioner is in use especially if there is also a gas appliance in use in this room Failure to follow these directions may result in a loss of oxygen in the room WARNING To prevent e...

Страница 23: ...impossible Symptoms Causes Reason and Disposal The fan speed can not be changed Check whether the MODE indicated on the display is AUTO Check whether the MODE indicated on the display is DRY When the...

Страница 24: ...neutral line is short circult if there is a water pump 1 Check whether the water pump is normal 2 Check whether the water level switch is normal 3 Check whether the water level switch is connected if...

Страница 25: ...pressure protection Outdoor coil sensor fault 1 Check whether the sensors are connected Running 3 4 5 7 Outdoor exhaust sensor fault 6 6 6 6 Please see the pasted diagram instruction on the unit first...

Страница 26: ...re or time by 1 unit Increase the temperature or time by 1 unit To switch the conditioner on and off To set automatic switching on off To select the fan speed of auto low mid high No 5 11 6 4 MODE DIS...

Страница 27: ...FYING indicator FAN ONLY OPERATION indicator HEATING indicator TIMER OFF indicator TIMER ON indicator AUTO FAN indicator LOW FAN SPEED indicator MIDDLE FAN SPEED indicator HIGH FAN SPEED indicator SLE...

Страница 28: ...peed 2 and the direction of the air flow 3 by pressing the keys indicated The appliance is fitted with a Hot Start function which delays appliance to startup in a few seconds to ensure an immediate ou...

Страница 29: ...e timed stop is programmed with the appliance on Press TIMER Set the time pressing the key or Press the key more times till on the display you can read the time which passes between the programming an...

Страница 30: ...ensure user comfort To optimize the working of the conditioner adjust the temperature only 2 1 the speed 2 and the direction of the air flow 3 by pressing the buttons indicated To activate the SLEEP...

Страница 31: ...ime expired nominal life time expired NOTE Do not use an old battery together with a new one Do not use an old battery together with a new one Remove cells when the remote controller is not Remove cel...

Страница 32: ...ration by TIMER ON OFF Mechanism Mechanism Checking of the room temperature Checking of the room temperature starts 60 minutes ahead of the timer starts 60 minutes ahead of the timer ON time Depending...

Страница 33: ......

Отзывы: