![Olivetti DF-670 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/olivetti/df-670/df-670_service-manual_3955614036.webp)
3LB
1-5-3
(3) Cleaning the staple
During periodic maintenance, remove all the staples remaining inside the machine due to failure of stapling.
Procedure
1. Open the front and left covers of the
machine.
2. Open the staple cover and then remove the
staple cartridge.
Figure 1-5-3
3. Remove the clip holder.
4. Remove three screws securing the staple
cover and then the cover.
Figure 1-5-4
5. Remove the staples attracted to the magnet
on the inside of the staple cover.
6. Refit the staple cover, staple cartridge and
clip holder.
7. Close the left and front covers.
Figure 1-5-5
Staple
cartridge
Staple cover
Screw
Screw
Screw
Clip holder
Staple cover
Magnet
Staple
Y108690-3 Service Manual
Содержание DF-670
Страница 1: ...Option Copier Service Manual Code Y108690 3 DF 670...
Страница 3: ...This page is intentionally left blank...
Страница 9: ...This page is intentionally left blank...
Страница 11: ...3LB This page is intentionally left blank...
Страница 15: ...3LB 1 1 4 This page is intentionally left blank Service Manual Y108690 3...
Страница 19: ...3LB 1 2 4 3 Remove the tape from the process table Figure 1 2 4 Tape Process table Service Manual Y108690 3...
Страница 43: ...3LB 2 1 6 This page is intentionally left blank Service Manual Y108690 3...
Страница 47: ...3LB 2 2 4 This page is intentionally left blank Service Manual Y108690 3...
Страница 54: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 10 2007 1ST EDITION 54 Y108690 3...