10. Service Mode
Field Service Ver. 1.0 Jun. 2008
214
Adjustment / Setting
Mode
Default value
389
Bit
7654 3210
HEX: 0C
State
0000 1100
Bit
Setting item
Setting value
Description
0
1
5-4
Specify coding format
Selects the coding method for SSL/TLS.
00
3DES_168bits/RC4_128
bits/DES_56 bits or
RC4_40 bits
01
RC4_128 bits/DES_56
bits or RC4_40 bits
10
DES_56 bits or RC4_40
bits
11
Not available
3
Enable Write function
Disable
Enable
Specifies whether to
enable the Write function.
2
Enable Discovery User
Disable
Enable
Specifies whether to
enable Discovery User.
Mode
Default value
390
Bit
7654 3210
HEX: A4
State
1010 0100
Bit
Setting item
Setting value
Description
0
1
7-6
Read security level
Selects the security level for Read User
authentication.
00
Not authenticate
01
auth-password
10
auth-password/priv-pass-
word
11
Not available
5-4
Write security level
Selects the security level for Write User
authentication.
00
Not authenticate
01
auth-password
10
auth-password/priv-pass-
word
11
Not available
2
PDF profile reception restriction
Disable
Enable
Sets whether to receive
no Profile, or Profile 4 or
later.
1-0
JPEG compression method
00
Standard compression
01
Low compression
10
High compression
11
Not available
d-Color MF201