FILTER/REGULATOR/LUBRICATOR UNIT
1. PRESSURE GAUGE
The pressure for the air system is shown on this pressure gauge. Working
air pressure can be adjusted by turning the pressure regulator located on
the filter bowl. Turn it clock-wisely for increasing pressure. Turn counter
clock-wisely for decreasing pressure. Lift the regulator knob·before setting
pressure. Push it down to fix the pressure setting after the pressure has
been adjusted. The working air pressure should be set at 5-6kg/cm2.
2. LUBRICATION BOWL
Periodically check to make sure that there is an adequate amount of oil in the
lubrication bowl. If necessary, fill oil into the lubrication bowl to 80% of the bowl
capacity to ensure that the air circuit is properly lubricated.
3. FILTER BOWL
Always remember that the moisture contained in air will condense and collect
in the filter bowl. The accumulated water in the filter bowl needs to be released
when the water level reaches a certain level. To release water simply pull back
the AIR ON/OFF CONTROL COLLAR on the quick air connector.
PRESSURE ADJUST KNOB
LUBRICATION
BOWL
UICK AIR CONNECTOR
AIR ON/OFF
CONTROL COLLAR
FILTER BOWL
WATER DRAIN
PORT