4265C Jointer
Digital Readout (DRO
)
This jointer is equipped with a Wixey DRO with
0.005”/0.05mm resolution.
On/Off Button
To turn on/off this DRO. It is also for calibration
in ABS (absolute) mode.
MM/IN Button
Toggles between measurement unit inch and
mm. When the reading gets close to a multiple
of 1/32, its fractional value will show on the
screen.
ABS/INC Button
Toggles between
Absolute
and
Incremental
mode.
The absolute mode shows the total depth of cut.
Once calibrated, the setting will be memorized
unless the battery is exhausted, OR if a user
recalibrates the DRO.
The incremental mode shows the distance
infeed table traveled since the last reset. The
readings can be reset by leaving the incremental
mode.
DRO Calibration
1.
Disconnect jointer from power source!!
2.
Set infeed table depth of cut to zero.
3.
Turn on DRO and switch to ABS mode.
4.
Hold the ON/OFF button for 3-5 seconds
until “ABS” is blinking on display. As the
button is released, readings will be reset to
zero.
5.
Press the ON/OFF button again to leave
calibration mode.
Содержание 4265C
Страница 2: ......
Страница 10: ...10 Page Oliver Machinery 4265C Jointer Identification...
Страница 11: ...4265C Jointer OLIVERMACHINERY NET 11 Page...
Страница 52: ...52 Page Oliver Machinery 4265C Jointer Wiring Diagram For Stock 4265C 101 4S 230V 1Ph...
Страница 53: ...4265C Jointer OLIVERMACHINERY NET 53 Page For Stock 4265C 102 4S 230 460V 3Ph...
Страница 54: ...54 Page Oliver Machinery 4265C Jointer Parts List Fence Assembly...
Страница 55: ...4265C Jointer OLIVERMACHINERY NET 55 Page Table and Cutterhead Assembly...
Страница 56: ...56 Page Oliver Machinery 4265C Jointer Base Assembly...
Страница 57: ...4265C Jointer OLIVERMACHINERY NET 57 Page Motor and Cabinet...
Страница 67: ...4265C Jointer OLIVERMACHINERY NET 67 Page Maintenance Record Date Task Operator...
Страница 68: ...68 Page Oliver Machinery 4265C Jointer Notes...