Electrical Connections
4. Replace the blade followed by the flange
and arbor nut. Tighten the arbor nut while
holding the arbor in place.
WARNING!
Electrical connections and wiring must be
done by a qualified electrician. The machine
must be properly grounded. Failure to
comply may cause serious injury!
Note:
Make sure the blade and arbor are clean
before installing a new blade. The blade teeth
should point down when viewing from the front
of saw.
This saw is available in both 1-Phase and 3-
Phase versions.
•
Electrical Connections for a 3-Phase Unit
This saw is 3-Phase, 220V/440V
pre-wired
220V
. If you need to switch the tablesaw from
220V to 440V have a qualified electrician make
the changes. Oliver Machinery recommends
using a dedicated circuit.
Make sure the voltage of your power supply
matches the specifications on the motor plate of
the machine.
With 3-Phase power verify the blade is turning in
the proper direction. Turn the saw on and make
sure the direction of the blade spins toward the
user when standing in front of the saw. If it does
not, disconnect the power source and reverse
any two power leads.
Figure 25
•
Electrical Connections for a 1-Phase Unit
This saw is 1-Phase, 220V only. Oliver
Machinery recommends using a dedicated
circuit.
Make sure the voltage of your power supply
matches the specifications on the motor plate of
the machine.
Replacing the Blade
The blade guard has been removed for photos,
but it is possible to change the blade without
removing the blade guard.
1.
Disconnect saw from power source.
2. Remove the table insert and raise the blade
completely.
3. Use the two provided arbor wrenches to
loosen the arbor nut, as shown in Figure 25.
Place one wrench on the arbor nut and one
on the flats located on the arbor. Remove
the nut, flange and blade.
13