28
29
8a
X1
Y3
Y2
Y1
EN - 28
ENGLISH
Values >0 increase the Tset in heating, increasing machine power (for instance, if
Tset=24°C and Energy boost = 3°C, the machine works if the Tset is 27°C)
To configure the appliance at the activation of one of the two functions, proceed as
follows:
a
. Undo the screws (3a) and (1b) and remove the cover (6) of the appliance (fig.
25).
b
. Undo the six fixing screws (X1).
c
. Remove the switchgear cover (3a) (fig. 28).
d
. From the screw clamp (Y2), remove the supplied bridge (Y3) (fig. 29).
e. Close the cover of the switchgear (3a) through the six screws (X1).
f.
Reassemble the front cover of the machine.
The inlet must be driven by a potential-free contact.
Do not use a cable longer than meters 10.
2.6.3 - Input setting configuration
In the configuration of the open or closed contact, the display shows
.
To set the desired configuration, carry out the previously described procedures and
choose between the parameter
(closed contact) or
(open contact).
2.6.4 - Temperature unit of measurement configuration
In the configuration of the unit of measurement of temperature, the display shows
.
To set the desired configuration, carry out the previously described procedures and
choose between the parameter
(metric system) or
(imperial system).
2.6.5 - Heat pump / only cooling / only heating configuration
During configuration of the mode of operation of the unit, the display shows
.
To set the machine so as that it works both in cooling and in heating mode, select the
“HP
” configuration (heat pump).
To set the machine so as that it works in cooling mode only, select the “CO
” config
-
uration (cooling only).