2.4.4 - Preparing the holes on the machine
The unit is designed exclusively for coupling with pipes for the exit and entry of air
with a diameter of 162 mm.
2.4.5 - Positioning of the device on the anchor brackets
Working on the two previously drilled holes
(see fig. 6), fix the support brackets (L) to
the wall using the supplied wall plugs screws
(E) (fig. 21).
After checking:
that the fixing brackets are well an
-
chored to the wall,
that the installation site has been
prepared for electrical connection and
condensation discharge (if necessary),
it is possible to hook the air conditioner.
Work as follows:
a.
Apply adhesive tape (A) to have refer-
ences to the hooking points of the unit
(fig. 22).
The tape can be removed once the unit
has been hooked to the wall.
b. Raise the air conditioner holding it by
the sides of the lower base and hook
it to the brackets (L) (fig. 23).
Slightly tilt the lower part of the ap-
pliance towards yourself to ease the
operation.