background image

5

• Material: High quality, impact and UV-resistant ABS colour RAL 9010.

• Design front cover removable for cleaning without the use of tools.

• Rear reinforcement ring to prevent spigot deformation during installation.

• High  efficiency  aerodynamic  fan  with  “winglet”  blades  to  optimise  quietness  and 

efficiency.

• Single phase EC Brushless motor with integral thermal protection.

• Motor mounted on high quality ball bearings.

• The fan is double insulated: no earth connection is required.

• Trickle speed selectable during installation: 6, 8, 13 l/s or off. 

• Option to boost from trickle (or from off) through LS connection or pull cord (only pull 

cord versions).

• Installation type selection available (through wall or ducted).

• Timer and Integral Humidistat versions available.

• IPX4 degree of protection.

• Power supply 220V to 240V~ 50/60Hz.

TECHNICAL SPECIFICATIONS

• Ensure adequate air return into the room in compliance with existing regulations in 

order to ensure proper device operation.

• If the environment in which the product is installed also houses a fuel-operating device 

(water heater, methane stove etc., that is not a “sealed chamber” type), it is essential 

to  ensure  adequate  air  intake,  to  ensure  good  combustion  and  proper  equipment 

operation.

• Install the product so that the impeller is not accessible from the air outlet side as 

verified  by  contact  with  the  Test  Finger  (test  probe  “B”  of  the  norm  EN61032)  in 

compliance with the current safety regulations.

• Ceiling installation 

  In order to guarantee the IPX4 degree of protection against moisture in case of ceiling 

installation, use the appropriate ceiling mount kit, which is not included. Use only the 

rear entry hole for supply cables. If there is a possibility of condensation along the air 

discharge duct, provide a drainage system to prevent condensation from discharging 

into the environment through the fan. 

  Attention: do not mount the product on the ceiling without this kit.

• Window installation 

  In case of window installation it is  necessary to use the appropriate window kit, which 

is not included. 

  Attention: do not mount the product on the window without this kit.

Model

Airflow

Static pressure

Pa max

Power

W max

Sound pressure

dB(A) @3m

SITALI SFE 100

m

3

/h 

l/s

27

2,5

26/23/13/11

83/47/29/21 23,1/13/8/6

INTRODUCTION

SITALI SFE 100 (fig. 1) is a decentralised mechanical ventilation unit designed to ensure 

air extraction in small/medium-sized rooms.  

Suitable for air discharge directly to the outside or in the presence of short ducted system. 

Wall, ceiling or window installation (fig.2).

Содержание SITALI SFE 100

Страница 1: ...lle normative vigenti Prima di collegare il prodotto alla rete di alimentazione o alla presa elettrica accertarsi che i dati di targa tensione e frequenza siano rispondenti a quelli della rete di dist...

Страница 2: ...tire l ottimale passaggio dell aria Assicurare un adeguato rientro dell aria nel locale nel rispetto del regolamento vigente al fine di garantire il corretto funzionamento dell apparecchio Qualora nel...

Страница 3: ...no collegamento come fig 14 Quando l interruttore esterno attivato il ventilatore funziona alla velocit massima Boost Spegnendo l interruttore esterno il ventilatore continua a funzionare alla velocit...

Страница 4: ...he electrical power supply socket is adequate for maximum device power If not contact a qualified technician The device should not be used as an activator for water heaters stoves etc nor should it di...

Страница 5: ...e to ensure good combustion and proper equipment operation Install the product so that the impeller is not accessible from the air outlet side as verified by contact with the Test Finger test probe B...

Страница 6: ...speed for a factory set period of time then returns to selected trickle speed Operation with external switch connected according to the diagram in figure 14 When the external switch is turned on the f...

Страница 7: ...tallation lectrique laquelle le produit est raccord doit tre conforme aux normes en vigueur Avant de brancher le produit au r seau d alimentation ou la prise lectrique assurez vous que les donn es de...

Страница 8: ...refoulement avec le Doigt d Essai sonde de test B de la norme EN61032 conform ment aux normes contre les accidents en vigueur Installation au plafond En cas d installation au plafond afin de garantir...

Страница 9: ...es vitesses minimales et maximales Lorsque le pourcentage d Humidit Relative passe en dessous du seuil l extracteur continue de fonctionner la vitesse moyenne pendant une dur e d finie lors de la fabr...

Страница 10: ...el ctrica y p ngase en contacto con personal cualificado lo antes posible En caso de reparaci n solicitar exclusivamente piezas de recambio originales El sistema el ctrico al que se encuentra conectad...

Страница 11: ...o que el rotor permanezca inaccesible al lado de la en trada al contacto con el Dedo de Ensayo sondas de prueba B de la norma EN61032 seg n las normativas vigentes sobre prevenci n de accidentes Insta...

Страница 12: ...a el ventilador funciona a velocidad m xima Boost Cuando se apaga el interruptor externo el ventilador sigue funcionando a velocidad m xima por un per odo de tiempo regulable para luego volver a la ve...

Страница 13: ...tto accessorio a richiesta ceiling accessory on demand plafond accessoire sur demande techo accesorio a pedido finestra accessorio su richiesta window kit on demand Kit fen tre sur demande ventana acc...

Страница 14: ...3 II 1 2 47 0 0255 21 III 1 7 47 0 0362 23 2 sound pressure level 3m in free field Curve Setting 1 W max m3 h max A DIP 001 1 0 27 B DIP 010 1 1 33 C DIP 101 1 1 35 D DIP 110 1 2 39 E DIP 011 1 5 53 F...

Страница 15: ...15 4 6 3 5 SITALI SFE 100 99 mm 7 8 6 MONTAGGIO E COLLEGAMENTI ELETTRICI MOUNTING AND ELECTRICAL WIRING MONTAGE ET BRANCHEMENTS ELECTRIQUES MONTAJE Y CONEXIONES EL CTRICAS...

Страница 16: ...16 4 x 5 mm 9A 10A 11A 13A 12A 10mm d d CAVO A PARETE SURFACE CABLE C BLE MUR CABLE DE PARED H03VV F H05VV F 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 HT...

Страница 17: ...17 11B 12B 13B 10B 9B 4 x 5 mm CAVO SOTTOTRACCIA RECESSED CABLE ENTRY C BLE SOUS GAIN CABLE DE TUBER AS H03VV F H05VV F 3 X 0 5 1 5 mm2 4 X 0 5 1 mm2 HT...

Страница 18: ...wall Expulsi n directa 21m3 h 6l s espulsione diretta through wall Expulsi n directa 29m3 h 8l s espulsione diretta through wall Expulsi n directa 47m3 h 13l s canalizzato in room canalizado OFF cana...

Страница 19: ...19 22 23 24 25 26 MANUTENZIONE PULIZIA MAINTENANCE CLEANING MAINTENANCE NETTOYAGE MANTENIMIENTO LIMPIEZA...

Страница 20: ...el m ximo caudal W 2 6 j Livello potenza sonora LWA Sound power level LWA Niveau de puissance acoustique LWA Nivel de potencia sonora LWA dBA 44 k Portata di riferimento Reference flow rate D bit de...

Страница 21: ...nnual electricity consumption warm climates Consommation d lectricit annuelle CEA en climat chaud Consumo anual de energ a AEC climas calientes kWh 0 2 v2 Consumo annuo di energia AEC climi temperati...

Страница 22: ...esult in administrative sanctions as provided by law DISPOSAL AND RECYCLING Information sur l limination des appareils en fin de vie Ce produit est conforme aux Directives de l Union Europ enne 2002 9...

Страница 23: ...23 NOTES...

Страница 24: ...triale 1 3 25060 Cellatica BS www olimpiasplendid it info olimpiasplendid it I dati tecnici e le caratteristiche estetiche dei prodotti possono subire cambiamenti Olimpia Splendid si riserva di modifi...

Отзывы: