
US-ENGLISH
US-ENG- 18
3.6.6 -
Operation in “Fan” mode
• In this mode the unit does not perform any function as it relates to temperature and humidity in the room.
• To activate: Press several times button
B5
on the remote control until when the automatic fan symbol
D18
(fan + first notch) appears on its display.
3.6.7 -
Operation in “Spa” mode (Automatic)
• In this mode the unit’s temperature is regulated according to the room’s temperature. The fan speed is
also regulated according to the temperature setpoint (except in dehumidification mode).
• To activate this mode, press the
B5
button on the remote control until the
D5
symbol appears on the
display.
3.6.8 -
Operation in “Heating” mode (heat pump models only)
• When the unit operates in heating the refrigeration system is in “reverse cooling” mode.
• To activate: Press the
B5
button on the remote control until the
D1
symbol appears on its display.
• In this mode, the required temperature and fan speed can be set by the user. After a maximum of 3 min
-
utes the compressor will start and the unit begins heating the space.
The unit will need to periodically enter defrost mode. During this operation the unit
does not heat the room, though its internal parts remain on except for the room
air fan. When the outdoor temperature is very low, there may be a slight delay as
the unit goes from minimum to maximum speed from when the command is sent
to the unit from the remote control. Similar delays might occur on activating the
swinging function of the mobile baffle. After having turned off the unit, the internal
fan runs for a brief period before stopping, then both air flaps close.
3.6.9 -
Checking airflow direction
• Press the
B4
button on the remote control to activate/deactivate the continuous oscillation of the moving
air outlet deflector (fig.A - ref. 1).
• When continuous oscillation is active, an additional press of the button
B5
allows to lock the deflector so
as to obtain the desired vertical direction for the air flow.
The moving deflector flap must never be forced manually.
3.6.10 - Checking fan speed
• The fan speed check occurs through button
B2
(on the remote control).
• Pressing this button several times will cause speed to change according to the following sequence:
low > medium > High > auto
• Higher fan speeds provide greater capacity with a corresponding increase in sound.
• In Auto mode the unit adjusts the fan speed. The higher the difference between the room temperature
and the user selected setpoint, the higher the speed.
• As the room temperature nears the setpoint, fan speed is reduced automatically.
• In dehumidification mode, it is not possible to control the speed as the unit can only operate at low speed.
Содержание maeStro Pro
Страница 1: ...INVERTER 12HP ENG INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE...
Страница 2: ......
Страница 6: ...min 60mm min 80mm 3 2 min 60mm 2 4 min 100mm 2 4 4 2 3...
Страница 7: ...M Y 4 5 B N 8mm 3 6 H H 7 6...
Страница 8: ...min 300mm 12 8 9 202 mm G 162 mm 130 mm G 8 6 5 5 1 10 12 11 G G...
Страница 9: ...F D F 13 14 6mm 1 4 15 17 16 18 F E E...
Страница 10: ...19 20 E 22 A B 21 W...
Страница 11: ...23 A B H H L L 26 24 25 L L 27 A A A A A...
Страница 12: ...28 29 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a 1c 32 X3 X3 X4 30 31 X1 X2 X2...
Страница 13: ...34 J1 J2 33 J1 J2 35 8m 26 36 37...
Страница 14: ...41 40 F F2 F1 F F2 F2 F1 F1 43 3 3 42 F min 80mm 3 2 39 3 F 38 10 7...
Страница 15: ...44 45 6 min 5 L 5 qts 6a...
Страница 16: ...46 47 Y2 Y2 Y3 Y3 Y1...
Страница 43: ......