background image

MAESTRO PRO INVERTER

MODE

Display

LED5

LED1

US-ENGLISH

US-ENG- 13

3 -  UNIT OPERATION

3.1 -  WARNINGS

The installation and electrical connections of the unit should be carried out by a service technician 

qualified as per local, state or national requirements.

 No structural object (furniture, curtains, plants, leaves, blinds, etc.) should ever 

obstruct the normal flow of air from either the internal or external gratings.

• Never lean or sit on the unit as this could cause serious damage or personal injury.

• Do not move the air outlet flap by hand. Always use the remote control to adjust baffle position.

• If the unit leaks water, switch it off immediately and disconnect it from the power mains. Call

the nearest service center or local licensed contractor.

• When the unit is heating, it has to periodically eliminate ice or frost that could form on the coil.

While in defrost mode the unit keeps running but does not heat the room. Depending on ambient 

conditions the lenth of time the unit will be in defrost will vary from 3 to10 minutes.

• Clean the air filter as often as required by the application and as described in paragraph (4.1.2).

 The unit must not be installed in rooms where explosive gas could be present 

or where there are conditions of heat and humidity beyond the maximum limits 

indicated in the technical specifications.

3.2 -  DESCRIPTION OF THE WARNING PANEL 

In the upper right part of the unit is the unit’s control display with LEDs, whose functions are described below.

Buttons

Before performing the following operations, press one of the 

buttons to enable the unit’s display.

+

Increase in the desired temperature, maximum value

settable is 86ºF (30ºC).

-

Decrease in the desired temperature.

minimum value settable in heating mode is 61ºF(16°C)

in cooling mode is 64°F (18°C).

Activation/deactivation (Stand-by) of the unit and fan

speed selection.

- Brief tap to select minimum, medium, maximum or automatic speed.

- Prolonged press for activation/deactivation (Stand-by).

MODE

   Operation mode selection and parameters setting

- Brief tap (for more than 2 seconds) to select fan, cooling or heating modes

- Prolonged press to enable parameters setting if in Stand-by mode

+

and

 

-

   Should be pressed simultaneously for at least 5 seconds to enable/disable the keypad lock function

and MODE

  Should be pressed simultaneously and for an extended period of time (at least 5 seconds)

to reset the dirty filter error fault code to zero.

Others

IR

  infrared Receiver

B

 Buzzer

Содержание Maestro Pro Inverter 12 HP

Страница 1: ...ENG INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE Maestro Pro Inverter 12 HP with 2 0 kw electric heat Model 02234 INVERTER 12HP...

Страница 2: ...out proper supervision 4 Ifthepowercableisdamaged itmustbereplacedbythemanufacturerorbyitstechnical support service or by similarly qualified personnel to prevent any risk to the user 5 Installation i...

Страница 3: ...FRA ENG DIRECTIVES D INSTALLATION D UTILISATION ET D ENTRETIEN INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE ESP INSTRUCCIONES DE INSTALACI N USO Y MANTENIMIENTO 1 D E P G O H N L F A B M C...

Страница 4: ...min 60mm min 80mm 3 2 min 60mm 2 4 min 100mm 2 4 4 2 3...

Страница 5: ...M Y 4 5 B N 8mm 3 6 H H 7 6...

Страница 6: ...min 300mm 12 8 9 3 4 202 mm G 162 mm 130 mm G 8 6 5 5 1 10 12 11 G G...

Страница 7: ...F D F 13 14 6mm 1 4 15 17 16 18 F E E...

Страница 8: ...19 20 E 22 A B 21 W...

Страница 9: ...23 A B 26 24 25 L 27 H L L...

Страница 10: ...28 29 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a 1c 32 X3 X4 30 31 X1 X2 X2...

Страница 11: ...34 J2 J1 33 J2 J1 35 8m 26 36 37...

Страница 12: ...41 40 F F2 F1 F F2 F2 F1 F1 43 3 3 42 F min 80mm 3 2 39 3 F 38 10 7...

Страница 13: ...44 45 6 min 5 L 5 qts 6a...

Страница 14: ...46 47 48 Y2 Y2 Y3 Y3 Y1...

Страница 15: ...installations 11 2 6 ENERGY BOOST SYSTEM DRY CONTACT INPUT 12 2 7 UNIT OF MEASURE SELECTION Celsius Fahrenheit 12 3 UNIT OPERATION 13 3 1 WARNINGS 13 3 2 DESCRIPTION OF THE WARNING PANEL 13 3 3 CONTRO...

Страница 16: ...RVICE Index Paragraphs marked with this symbol contain very important information and recommendations particularly as regards safety Failure to comply with them may result in danger of injury to the o...

Страница 17: ...contains useful information for understanding the use and programming of the conditioner and themost common maintenance interventions 2 This document contains proprietary information protected by law...

Страница 18: ...he appliances and respect anything suggested by common sense and those of the Safety Norms in force in the place of installation 10 Always wear Personal Protection Devices when servicing the unit Thes...

Страница 19: ...1 3 RECEIPT AND UNPACKING The products are packaged by qualified personnel using suitable packaging material The units are shipped complete and in perfect condition when leaving our facility However...

Страница 20: ...selecting an air conditioner or heat pump it is essential to make an accurate calculation of the heat load including sensible and latent gains for cooling mode and for heat pumps the sensible loss for...

Страница 21: ...e supply air flap fig 3 j Do not place bottles cans clothes flowers or any other object on the return air grille fig 3 k Do not install the unit directly on another household appliance TV radio fridge...

Страница 22: ...the outside 2 4 2 Preparing the condensate discharge fig 6 7 A condensation drain line N must be inserted into the connection which can be accessed after opening the door under the unit and connected...

Страница 23: ...17 d Insert the two caps with spring on the front part of the external grille on its two housings pulling until it clicks fig 18 and couple the two chains to the large eyelet of the spring e Using one...

Страница 24: ...plate of the unit The power supply line is fitted with an efficient earth connection that is ap propriately sized for the maximum absorption of the conditioner minimum cross section of the cable must...

Страница 25: ...in the terminal board J2 fig 34 m Lock the cable with the clamp J1 fig 34 n Close the switchgear o Reassemble the front cover The above operation must be performed by a qualified and properly license...

Страница 26: ...st be performed by the installer or similarly qualified service technician as per local state and or national requirements To prevent the risk of an electric shock unplug or de energize the unit befor...

Страница 27: ...4 1 2 The unit must not be installed in rooms where explosive gas could be present or where there are conditions of heat and humidity beyond the maximum limits indicated in the technical specificatio...

Страница 28: ...N RED X Dehumidification mode ON BLUE X Ventilation mode OFF X Spa mode auto mode X X High fan speed X X Medium fan speed X X Low fan speed X X Automatic fan speed X X Timer enabled X X ON Filter dirt...

Страница 29: ...t cover b Insert the batteries into the compartment Check the polarity of the batteries as indicated on the bottom of the compartment c Close the compartment fig 36 3 4 2 Replacement the batteries Bat...

Страница 30: ...t together with button B7 to change temperature unit F C B7 Desired clock programming temperature decrease Press it together with button B6 to change temperature unit F C B8 Activation deactivation of...

Страница 31: ...in switch off or unplugging the unit 3 6 4 Operation in Cooling mode only When used in this mode the unit dehumidifies and cools the room To activate this mode press several times the button B5 on the...

Страница 32: ...iod before stopping then both air flaps close May be equipped with a electric heater that activates automatically as a back up source of heat to the compressor when operating in low ambient external t...

Страница 33: ...se timers first set the correct time see paragraph 3 6 13 and then set the timer as you prefer 3 6 13 Timer and clock setting To set time operate the remote control as follows a Press B9 button Set ti...

Страница 34: ...to one of the two programs or both In particular each time you press button B9 Set timer Programs activation situation changes as follows Use of Program 1 only Use of Program 2 only Use of Programs 1...

Страница 35: ...eration of unit the air filter has to be cleaned periodically The air filter is at the top of the unit Filter removal a Unplug or disconnect the unit from power b Switch off the unit and wait for the...

Страница 36: ...installation and operating instructions 4 2 2 Condensate water drainage in case of emergency Should the condensation management system get clogged or stop draining the unit stops and displays alarm c...

Страница 37: ...a blackout occur alarm code 50 will appear 4 3 3 Console alarms If one of the following alarms on the unit control display persists for more than three minutes please contact an Olimpia Splendid autho...

Страница 38: ...y Clean the air filter The doors or windows are open Close the doors or windows The air inlet or outlet vents of the indoor or outdoor units are blocked First remove the obstructions and then re start...

Страница 39: ...tarting the unit verify Supply Voltage to the unit _______ Install batteries in Remote Control Start Unit to verify operation and record requested values below The following values are to be recorded...

Страница 40: ...not affect product performance 14 Increases in utility costs and additional utility expenses 15 A completed data sheet available on www olimpiasplendidusa com must be submitted along with the warranty...

Страница 41: ...264098A Contact Information Olimpia Splendid USA 870 International Parkway Suite 120 Flower Mound TX 75022 Phone 800 408 5196 Ext 103 Email customerservice olimpiasplendidusa com...

Отзывы: