47
bracket for the external unitis wall-mounting" which is
available on request. As regards the assembly follow the
instructions enclosed in each respective box.
We would also like to indicate some precautions to be taken
during assembly:
In areas susceptible to snowfalls
By means of support walls or a base of metal sections the
appliance must be lifted above ground level at a distance
greater than the height of a maximum foreseeable snowfall
because:
- if the appliance does not work by heat pump, during the
thaw, the water could get into the system causing damage
to the electrical devices,
- if the appliance works by heat pump, the drifting snow
could obstruct the regular air circulation and make con-
densate drainage difficult.
Appliance assembly on ground level, roof, terrace, etc.
in not easily accessible locations
The base must be lifted to avoid stagnant rain water and dirt
accumulation underneath the appliance. It is therefore
advisable to raise the appliance approximately 15 cm off the
ground by means of two small walls onto which the appliance
is fixed with two anchor bolts. The above is not necessary,
however, if the appliance is to be installed on a balcony as
balconies already slope to aid rainwater drainage and are
usually found in fairly protected locations hence there should
be no danger of dirt accumulation under the appliance.
On a rigid metal base (Brackets, metal support sections,
etc.)
In this case the appliance must always be fixed to the base
by means of elastic vibration-damping blocks (not supplied
with the appliance) underneath the four support points
which are selected in relation to the applianceis weight.
Furthermore, the base must be rigid enough to avoid
amplifying the vibrations caused when the appliance is
running.
Heat pump appliances
When the heating is on, a condensate or water is produced
in the external unit due to defrosting. Such water must be
eliminated to avoid stagnation. In particular, when the
appliance is assembled directly on the ground a drainage
channel should be made around the base of the appliance
which depends on the drainage system running from the
building. If the appliance is installed on a balcony it is
possible to position it over a tray in galvanized sheet iron or
better still in stainless steel (not included with the appliance)
which remains above ground level and which is equipped
with a drainpipe from which the condensate can be made to
flow using the most opportune method (for example, into a
gutter).
Furthermore, even if the appliance is resistant in inclement
weather, it should be assembled in a location which remains
protected or it should be covered with its own roof which
permits the air to circulate freely through the appliance.
Содержание ClimaPiu 8 HE HP
Страница 1: ...MANUALE D INSTALLAZIONE MANUALE D USO MANUAL FOR INSTALLATION INSTRUCTIONS FOR USE...
Страница 2: ...37 Manual for Installation...
Страница 23: ...58 Instruction for Use...
Страница 36: ...71...