2.3 OPERATING
LIMITS
( g.10)
The
diagrams
in
g.10 de ne the water (LWT) and outdoor air (ODT) temperature limits within which the heat pump can run in
its two modes, domestic water cooling and heating/production, and cooling only.
2.4 REFRIGERANT
CONNECTIONS
( g. 11, 12)
To
de ne the refrigerant connection lines between the internal unit and the external unit, see the table below.
OS-
CEBSH24EI
OS-
CEBCH36EI
OS-
CEBCH48EI
OS-
CEBTH48EI
OS-
CEBCH60EI
OS-
CEBTH60EI
Maximum length of
connecting pipes (m)
25
30
50
50
50
50
Limit of elevation difference
between the two units if the
external unit is positioned
higher (m)
12
20
25
30
25
30
Limit of elevation difference
between the two units if the
external unit is positioned
lower (m)
9
12
20
20
20
20
Additional charge of
refrigerant per metre over 5
metres piping (g/m)
60
60
60
60
60
60
Use solely pipes with diameters that comply with the required dimensions (5/8 gas pipe, 3/8 liquid pipe).
The maximum length of the connecting lines to the internal unit must comply with table 1, topping up the charge of R410A as
envisaged (see sect. 2.4.2). Do not install the units beyond the maximum height difference permitted between the internal unit
and the external unit.
Complete the refrigerant circuit by connecting the internal unit to the external unit using insulated copper pipes.
Use solely insulated copper pipes speci c for cooling purposes, supplied clean and sealed at the ends.
The refrigerant connections of the internal unit are behind the electric panel; those of the external unit are on the right-hand side
and the safety panel must be removed in order to gain access.
A
5/8 gas line internal unit
B
3/8 liquid line internal unit
C
5/8 gas line valve external unit
D
3/8 liquid line valve external unit
Identify a route for the pipes that reduces the length and the bends in the pipes as much as possible to obtain maximum perfor-
mance from the system.
Insert the refrigerant lines into a suitably sized cable routing duct (if possible with internal separator) fastened to the wall for
routing the pipes and electrical wires.
Cut the lengths of pipe about 3-4 cm longer than the required length.
IMPORTANT: cut using a
ZK
eel pipe-cutter only, tig
K
tening at small intervals so as not to crus
K
t
K
e pipe.
•
Remove any burrs using an appropriate tool.
• Before
aring, insert the fastening nut into the pipe ( g.12A).
•
Flare the ends of the pipes impeccably, without cracks, wrinkles or folds, using a special tool ( g.12B).
•
Manually tighten the pipe nut onto the thread of the tting.
• De
¿
nitively tig
K
ten using a
¿[
ed
Z
renc
K
to
N
eep t
K
e t
K
readed part of t
K
e
¿
tting stationary to prevent deformation,
and a dynamometric
Z
renc
K
on t
K
e nut (
¿
g. 13) calibrated
Z
it
K
t
K
e follo
Z
ing values depending on t
K
e size of t
K
e
pipes:
•
Diameter 3/8’’ 34 N.m < tightening torque < 42 N.m
•
Diameter 5/8’’ 68 N.m < tightening torque < 82 N.m
Содержание BIG
Страница 2: ...2 1 3 2 A M L O N R H G Q I B E D P F C K ...
Страница 3: ...3 5 4 6 A B C A B ...
Страница 4: ...4 8 D D D D C D A D H G G I F E B D 9 30cm 60 cm 30 cm 15 cm 30 cm 60cm L A A 7 ...
Страница 6: ...6 17 16 A B E F E G H C D 18 15 14 C D A B A H B C D E F E G ...
Страница 8: ...8 24 23 22 ...
Страница 11: ...11 ...
Страница 35: ......
Страница 59: ......
Страница 83: ......
Страница 107: ......
Страница 108: ...www olimpiasplendid it info olimpiasplendid it 277228C ...