User Manual LR-1BS35
OMEN-1BS35-202012
4
Definition of Ethernet interface
Figure 5 Diagram of interface
4.3.
Communication interface
The LR-1BS is connected to the computer by a standard Ethernet RJ-45 interface. The
computer IP address should be set up before communication. The lidar and computer IP must
be set up in the same subnet without any conflict. The port number of the point cloud data
package is 2368 by default.
The factory default settings are as follows
Computer IP
:
192.168.1.10
Computer subnet mask
:
255.255.255.0
The default factory settings of lidar are as follows
Lidar IP
:
192.168.1.100
Lidar subnet mask
:
255.255.255.0
The setting processes on the computer are as follows
Figure 6 Step 1 of computer IP setting