OLCT 200 User Manual |
16
2.4.1
10-0322 Magnetic Mounting Option
The 10-0322 Magnetic Mount securely attaches the assembly to solid steel structure
that is at least 6 inches wide.
2.5 System Design Specifications
Supply Voltage:
2 Wire Model
3 Wire Model
10-30VDC
Wireless Model
Battery Powered
Wireless Model
10-30VDC
10-30VDC
10-30VDC
Integral non-
rechargeable 3.6volt
19AH lithium D cell
battery.
Replacement P/N
10-0293.
Power Consumption:
2 Wire Model
3 Wire Model
10-30VDC Wireless
Model
Battery Powered
Wireless Model
25mA max @
24VDC
100mA @ 24VDC
with 0.5watt sensor.
Relays: +40mA per
relay (120mA for
three energized
relays)
RS-485: +20mA
<20mA -
“sleep”
mode
60mA
– “receive
beacon” mode
Up to 1amp
– 1
watt “transmit”
mode. Transmit
power can be set
from 10mW
– 1W.
<2mA -
“sleep”
mode
40mA
– “receive
beacon” mode
Up to 1amp
– 1
watt “transmit”
mode. Transmit
power can be set
from 10mW
– 1W.
Loop Resistance at nominal 24 VDC power:
2 Wire Model
3 Wire Model
10-30VDC Wireless
Model
Battery Powered
Wireless Model
650 ohms
750 ohms
n/a
n/a
Memory:
Non-volatile E2 memory retains configuration values in the event of power outages.
Содержание OLCT 200
Страница 4: ...OLCT 200 User Manual 4...
Страница 14: ...OLCT 200 User Manual 14 Figure 2 3a Outline Drawing OLCT 200 Wired Models...
Страница 19: ...OLCT 200 User Manual 19 2 6 2 Installation Drawing 11 0100...
Страница 32: ...OLCT 200 User Manual 32...
Страница 36: ...OLCT 200 User Manual 36...
Страница 38: ...OLCT 200 User Manual 38 Figure 4 1 Calibration Gas Input...
Страница 61: ...OLCT 200 User Manual 61 Figure 6 5...
Страница 62: ...OLCT 200 User Manual 62...
Страница 79: ...OLCT 200 User Manual 79...