Connect a voltmeter as indicated and
adjust, using potentiometer p5 (ref. 1).
The output signal must be equal to
880 mV.
■
Next, inject the calibration gas at a
flow rate of 30 l/h (refer to paragraph
Indications for calibrating the CTX
300 SC
, on page 45).
■
Wait for the signal to stabilize and
adjust the signal with the sensitivity
potentiometer p6 (ref. 2).
The output signal should be:
Figure 25
U = 880 mV + 3520 mV x Cal gas concentration
Sensor measurement range
Example
Sensor measure
(% of full range)
Output signal
(mV)
0
880
50
2 640
100
4 400
■
Stop injecting the calibration gas.
■
Verify that the reading returns to zero
(880 mV). If it does not, repeat the
entire procedure.
■
Calibration is complete.
■
Flip the switch (ref. 1) into the
MES
(Measure) position.
Figure 26
Содержание ctx 300
Страница 8: ...8 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 18: ...18 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 30: ...30 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 36: ...36 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 38: ...38 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 39: ...7 Certification 39 www acornfiresecurity com www acornfiresecurity com...
Страница 40: ...40 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 44: ...44 CTX 300 User manual www acornfiresecurity com www acornfiresecurity com...
Страница 47: ...9 Annex 47 Figure 28 CTX 300 overview www acornfiresecurity com www acornfiresecurity com...