![Oldham BM25 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/oldham/bm25/bm25_operating-manual_3709806021.webp)
22
V+ Trickle charge 1
V+ Trickle charge 2
V- Trickle charge 1
1
2
3
4
V- Trickle charge 2
1
2
4
3
V- Charge
V+ Charge
6
5
4
3
2
1
7
Mass logic
inputs
Logic input
Alarm
acknowledgement
Logic input
Alarm transfer
+ contact
Alarm relay
- contact
Alarm relay
+ contact
Relay fault
- contact
Relay fault
6
5
4
3
2
1
7
BACK
Top
To INDUSTRIAL
SCIENTIFIC- charger
(do NOT connect) in ATEX
area
External power supply
for trickle charging of
BM25 battery pack
Yellow ring
Option connector = logic input
SI Parameters:
-
Alarm contact Static type rela y Vin=30Vdc, Iin=150 mA, Lin=0 et Cin=0
-
External power supply for trickle charging U in =30V, I in=160 mA, Lin=0 et Cin=0
-
Logic input U out = 5 V, I out = 50 mA, L out = 8 mH, C out = 7 µF
Caution
: The responsible person must create an IS system log (see BM25 note)
Relay outputs and logic inputs
Mass logic
inputs
Logic input
Alarm
acknowledgement
Logic input
Alarm transfer
FRONT
ELECTRICAL REFERENCE FOR BM25 CONNECTORS
Figure 1