2) COMBUSTION AIR 

 

(a) WARNING: If the area in which the appliance is to be operated is smaller than 

750 

cubic  feet,  or  it  the  building  is  of  an  unusually  tight  construction, adequate 

combustion  and  ventilation  air  must  be  provided  by  one  of  the  methods 
described  in  the 

National  Fuel  Gas  Code 

ANSI  Z223.l/NFPA  54,  Air  for 

Combustion and Ventilation, or applicable local codes. 
 
Unusually tight construction is defined as construction where: 
 

(1) Walls  and  ceilings  exposed  to  the  outside  atmosphere  have  a  continuous 
water vapor retarder with a rating of 1 penn (6 x 10 “kg per pa-sec-m2) or less 
with openings gasketed or sealed; 
 
(2) Weather stripping has been added on openable windows and doors; and 
 
(3) Caulking or sealants are applied to areas such as joints around window and 
door  frames,  between  sole  plates  and  floors,  between  wall-ceiling  joints, 
between wall panels, at penetrations for plumbing, electrical, gas lines, and at 
other openings. 

 
(b) The Old Salem coal set has been equipped with an oxygen depletion system 
to prevent reduction of the oxygen level in the installation room from reaching a 
level  below  18  percent.  The  above  requirements  are  provided  to  prevent  the 
unlikely occurrence of this level

 

3) MINIMUM CLEARANCE TO COMBUSTIBLES: 

 

When  the  Old  Salem  ventfree  coal  burner  is  installed  in  a  non-combustible 
fireplace, the mantel, if used, may extend up to 12 inches maximum from the wall 
and  must  be  located  a  minimum  of  18  inches  above  the  top  of  the  fireplace 
opening.  The  underside  of  the  mantel  should  be  protected  by  a  high  temperature 
paint or application of a non combustible lamination. 
 
When  installed  in  a  corner  location,  there  must  be  a  minimum  clearance  of  10 
inches  from  the  outer  edge  of  the  fireplace  opening  and  the  corner  wall  with  the 
intervening  space  made  of  non  combustible  materials,  cast  iron  surround, 
masonry, tile etc. there must be a non combustible hearth extending a minimum of 
14 inches in front of the firebox. 
 
Overall minimum clearances to combustibles on the outside of firebox are: 
 
Sides: 6” 
Top: 18” 
Hearth: 14” 

 

Содержание R400IGV36 BV3ON

Страница 1: ...a neighbors phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agen...

Страница 2: ...Maximum BTU for Natural Gas 13 400 intake Maximum BTU for Natural Gas Bedroom unit 10 000 intake Minimum BTU for Natural Gas 9 000 intake INTRODUCTION The Old Salem Regency coal set is a ventless hea...

Страница 3: ...ever burn solid fuels in a fireplace where a gas coal set is installed e This unit complies with ANSI Z21 11 2 Unvented Heaters f The installation must conform with local codes or in the absence of lo...

Страница 4: ...q DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM r If heater shuts off do not relight until you have provided fresh air If heater keeps shutting off have it serviced Keep burner and control compartm...

Страница 5: ...ther openings b The Old Salem coal set has been equipped with an oxygen depletion system to prevent reduction of the oxygen level in the installation room from reaching a level below 18 percent The ab...

Страница 6: ...clean g WARNING any change to this heater or its controls can be dangerous h This appliance is intended for supplemental heating 5 NATURAL GAS PIPING a The installation must conform with local codes...

Страница 7: ...ipe be run through the masonry into the firebox area Using an approved flexible gas hose connect to line from the fixed pipe to the gas input to the appliance All pipe work going through masonry shoul...

Страница 8: ...touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 9: ...the next step 5 Push in gas control knob slightly and turn clockwise to Pilot 6 Depress the control knob fully and push spark igniter button several times to light the pilot 7 Continue to hold the con...

Страница 10: ...d the control knob down for 60 seconds 4 Contact your service technician or gas supplier to replace the defective unit The flame level has been preset for relatively small changes in BTU level At firs...

Страница 11: ...11 Note Basket is delivered with Jumper wire installed It must be removed for external switch or remote control to work Remove factory jumper when installing remote control...

Страница 12: ...n under water Immediately call a qualified service technician to inspect the appliance and determine if the appliance must be returned to the manufacturer for repair and calibration 11 TROUBLE SHOOTIN...

Страница 13: ...NOTE In the interest of product development and the introduction of any new relevant mandatory gas requirement the manufacturer reserves the right to modify and amend the appliance s and instructions...

Отзывы: