Old Salem Hearths R400IGV36 BV3ON Скачать руководство пользователя страница 4

 

resulting from improper installation or operation, can settle on surfaces outside 
the fireplace. 

 

(n) Note: Installation and repair should be done by a qualified service person. The 
appliance  should  be  inspected  before  use  and  at  least  annually  by  a  qualified 
service  person.  More  frequent  cleaning  may  be  required  due  to  excessive  lint 
from  carpeting,  bedding  material,  etc.  It  is  imperative  that  the  control 
compartment, burners and circulating air passageways of the appliance be kept 
clean. 
 
(o)  An  unvented  room  heater  intended  for  installation  in  a  solid-fuel  burning 
fireplace shall comply with these instructions. 
 
(p)  This  heater  is  equipped  with  a  PILOT  LIGHT  SAFETY  SYSTEM  designed  to 
turn off the heater if not enough fresh air is available. 
 
(q) DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM 
 
(r)  If  heater  shuts  off,  do  not  relight  until  you  have  provided  fresh  air.  If  heater 
keeps shutting 

off, 

have it serviced. Keep burner and control compartment clean. 

Call your installer or Old Salem Hearths. 
 
(s) It is critical that the burner be installed level to prevent sooting 
 

WARNING: Do not use this room heater if any part has been under water. 
 
WARNING: When used without adequate combustion air, heater may give off 
CARBON MONOXIDE, an odorless, poisonous gas. 
 
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may 
result in sooting and property damage. 

 

WARNING: State or local codes may not allow operation of unvented appliances. 
Check your state or local codes. 
 
WARNING: Any outside air ducts and/or ash dumps in the fireplace shall be 
permanently closed at the time of appliance installation. 
 
WARNING: Any glass doors shall be fully opened when the appliance is in 
operation.

 

 

Содержание R400IGV36 BV3ON

Страница 1: ...a neighbors phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agen...

Страница 2: ...Maximum BTU for Natural Gas 13 400 intake Maximum BTU for Natural Gas Bedroom unit 10 000 intake Minimum BTU for Natural Gas 9 000 intake INTRODUCTION The Old Salem Regency coal set is a ventless hea...

Страница 3: ...ever burn solid fuels in a fireplace where a gas coal set is installed e This unit complies with ANSI Z21 11 2 Unvented Heaters f The installation must conform with local codes or in the absence of lo...

Страница 4: ...q DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM r If heater shuts off do not relight until you have provided fresh air If heater keeps shutting off have it serviced Keep burner and control compartm...

Страница 5: ...ther openings b The Old Salem coal set has been equipped with an oxygen depletion system to prevent reduction of the oxygen level in the installation room from reaching a level below 18 percent The ab...

Страница 6: ...clean g WARNING any change to this heater or its controls can be dangerous h This appliance is intended for supplemental heating 5 NATURAL GAS PIPING a The installation must conform with local codes...

Страница 7: ...ipe be run through the masonry into the firebox area Using an approved flexible gas hose connect to line from the fixed pipe to the gas input to the appliance All pipe work going through masonry shoul...

Страница 8: ...touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Страница 9: ...the next step 5 Push in gas control knob slightly and turn clockwise to Pilot 6 Depress the control knob fully and push spark igniter button several times to light the pilot 7 Continue to hold the con...

Страница 10: ...d the control knob down for 60 seconds 4 Contact your service technician or gas supplier to replace the defective unit The flame level has been preset for relatively small changes in BTU level At firs...

Страница 11: ...11 Note Basket is delivered with Jumper wire installed It must be removed for external switch or remote control to work Remove factory jumper when installing remote control...

Страница 12: ...n under water Immediately call a qualified service technician to inspect the appliance and determine if the appliance must be returned to the manufacturer for repair and calibration 11 TROUBLE SHOOTIN...

Страница 13: ...NOTE In the interest of product development and the introduction of any new relevant mandatory gas requirement the manufacturer reserves the right to modify and amend the appliance s and instructions...

Отзывы: