OKM PULSE NOVA Скачать руководство пользователя страница 4

4 / 22

 1   INTRODUCTION

 1.1  PREFACE

Dear customer,

our engineers, sales, training and support staff at OKM GmbH would like to thank you for your 
purchase of the Pulse Nova metal detector.

The Pulse Nova pulse induction detector works on the principle of a time sensitive oscillator 
which produces an alternating current that passes through a coil producing an alternating mag-
netic field. This alternating magnetic field creates an eddy current which can detect electrically 
conductible metal. It uses the induction of a high voltage energy pulse to identify the presence 
of metals.

The Pulse Nova is able to locate buried objects within various structures and vessels non-intru-
sively without having to excavate the area. The facile and flexible handling of the Pulse Nova can 
easily and quickly give reproducible results.

Our team of specialists guarantees that our products are under recurrent control. Our special-
ists try to implement new developments in terms of further quality improvements for you.

By purchasing or using one of our products, we cannot guarantee that during the course of your 
research you will be successful and have a find. The recognition of hidden and buried objects 
depends on various factors. As you well may know there are different soil types all over the 
world with different levels of natural attenuation. Variable soil properties can and will hamper 
and alter ultimate scan measurements. Areas with an extreme amount of ground water, vary-
ing clays, sands and wet soils will make scanning more difficult and may reduce the maximum 
depth capabilities of any and all detection equipment, regardless of brand or model.

For more information regarding where our equipment has been used and operated, please visit 
our website. Our equipment is constantly being tested and when improvements or upgrades are 
available, we will list them also on our website.

It is necessary for our company to protect our developments and all of the information learned 
during the “Research and Development” phases in creating our technology. We strive to stay 
within the given framework of legislation, patents and trademark registration.

Please take your time to read this User Manual and familiarize yourself with the operation, 
functionality and how to use the Pulse Nova. We also offer training at our factory and on-site. 
We strive to maintain a worldwide dealer network for assistance and support. Please visit our 
website for more information.

INTRODUCTION

Содержание PULSE NOVA

Страница 1: ...INTRODUCTION TECHNICAL SPECIFICATIONS CONTROL ELEMENTS ASSEMBLY MEASUREMENT TROUBLESHOOTING OKM PULSE NOVA MANUAL ...

Страница 2: ...warranty In no circumstances OKM takes responsibility for lost profits usage or data losts interruption of business activities or all kind of other indirectly damages which developed because of errors in this documentation This instruction manual and all other stored media which are delivered with this package should only be used for this product Program copies are allowed only for security and sa...

Страница 3: ...DELTA38 OMEGA38 7 2 4 SEARCH COIL DELTA18 OMEGA18 7 2 5 FRAME COIL XI104 7 3 CONTROL ELEMENTS 8 3 1 CONTROL UNIT 9 3 2 TELESCOPIC ROD 11 3 3 SEARCH COILS 11 3 4 BLUETOOTH HEADPHONES 12 3 4 1 Pairing new Bluetooth Headphones 12 4 ASSEMBLY 13 4 1 CHARGING THE CONTROL UNIT 13 4 2 MOUNTING THE CONTROL UNIT 14 4 2 1 Attaching the Carrying Strap 14 4 2 2 Mounting the Control Unit 14 4 4 ADJUSTING THE TE...

Страница 4: ...and have a find The recognition of hidden and buried objects depends on various factors As you well may know there are different soil types all over the world with different levels of natural attenuation Variable soil properties can and will hamper and alter ultimate scan measurements Areas with an extreme amount of ground water vary ing clays sands and wet soils will make scanning more difficult ...

Страница 5: ...cated range of values Use only approved chargers batteries and rechargeable batteries which are included within the scope of delivery 1 2 5 Data Correctness Data errors can occur if the power supply of the device or the batteries are too low the cables are too long the unit is operating to close to devices which sends out disturbances or atmospheric conditions electrical storms lightning etc 1 3 M...

Страница 6: ...detector becomes less and less re sponsive and seems to have lost some of its original peak performance You can help prevent this from happening to your detector by following these basic care and protection guidelines Operate your detector exactly as recommended in this User Manual Use only the OKM Power Pack or other approved power supplies The search coil cable is hard wired to the search coil a...

Страница 7: ... 115 x 200mm Weight 0 90kg 2 3 SEARCH COIL DELTA38 OMEGA38 Diameter Ø 375mm Height 45mm Cable Length approx 1 50m Weight approx 0 80kg Technology Bifilar Mono Coil High Voltage Pulse Induction Waterproof Yes 2 4 SEARCH COIL DELTA18 OMEGA18 Diameter Ø 175mm Height 45mm Cable Length approx 1 50m Weight approx 0 38kg Technology Bifilar Mono Coil High Voltage Pulse Induction Waterproof Yes 2 5 FRAME C...

Страница 8: ...tal Detector with Standard Search Coil Delta38 The Search Coil is mounted at the bottom of the Telescopic Rod The Control Unit needs to be attached beneath the armrest detail Understanding the various ports and connectors makes it much easier to prepare the unit for operation Assembled Metal Detector with Standard Search Coil Delta38 The Search Coil is mounted at the bottom of the Telescopic Rod T...

Страница 9: ... place where it gets connected Slider Plate This part is used to mount the Control Unit to the Telescopic Rod Thanks to the embedded magnet the Control Unit will keep in place when attached Read chapter 4 2 Mount ing the Control Unit on page 14 to learn more about assembling and disassembling the Con trol Unit to the Telescopic Rod Headphones Socket If you don t want to use Bluetooth Headphones yo...

Страница 10: ... right raises the volume If the value reaches its minimum or maximum addition al turning in the same direction will have no decreasing or increasing effect In this case you will hear a double tone that indicates you reached the end of the adjustment range In case you need to connect Bluetooth Headphones the Volume Knob can be utilized for pairing purposes Please read chapter Pairing new Bluetooth ...

Страница 11: ...cro for your own comfort Tab Locks Use these locks to extend or shrink the Telescopic Rod Open the tab to loose the connected shaft of the rod and tighten it after adjusting the length accordingly More details in chapter 4 4 Adjusting the Telescopic Rod on page 15 3 3 SEARCH COILS The Pulse Nova metal detector comes depending on the purchased pack with several Search Coils in different sizes 38cm ...

Страница 12: ...cessful Bluetooth connection As soon as the Bluetooth connection between Control Unit and headphones has been estab lished the internal speaker will be disabled The Headphones Socket will not be disabled so any wired headphones that are connected to the Control Unit are still working independently 3 4 1 Pairing new Bluetooth Headphones To operate the Pulse Nova metal detector with any other wirele...

Страница 13: ...tor at all When the internal battery gets low while working with the detector a low triple tone at increasingly shorter intervals will sound on your acoustic output This very unique tone will repeat to inform you about the low battery condition until the Control Unit switches off Recharge the battery by connecting the Power Charger or an OKM Power Pack The Charging LED indicates the status of the ...

Страница 14: ...ap into the Loops of the Control Unit 4 2 2 Mounting the Control Unit When using the 18cm or 38cm Search Coil the Control Unit may be mounted to the Telescopic Rod 1 2 Place the Slider Plate of the Control Unit directly into the Slider Bracket of the Telescopic Rod Push it completely into the bracket until it snaps into place After the Control Unit has been attached to the Telescopic Rod you can c...

Страница 15: ...ated Socket of the Control Unit 4 4 ADJUSTING THE TELESCOPIC ROD The length of the Telescopic Rod can be adjusted according to your own body height Adjust the length according to your own comfort Use the Tab Locks to loosen and tighten the single segments of the Telescopic Rod To adjust the rod length the Tab Locks needs to be opened 2 Extend the shaft to your desired length To fix the length lock...

Страница 16: ...onto the Mounting Plate on top of the Telescopic Rod and push it gently to fix it You can remove the flashlight via the rubber band see steps 1 and 2 e g for charging The Pulse Nova metal detector includes an LED Flashlight that can be attached on the Tele scopic Rod This is very helpful for night searches or investigations in dark rooms or chambers ...

Страница 17: ...inting up Assemble the coil by putting each end into the adjacent corner piece Each segment is equipped with a belt clip to mount the carrying straps You may change the position of the belt clips to adjust it to your individual needs The carrying straps must be attached to the Frame Coil in order to carry it The coil can be carried by 2 people whereas each person carries one single strap or by 1 p...

Страница 18: ...tromag netic induction to create a reaction within metals This reaction within the metal object creates electrical conductivity or an anomaly which actually disturbs the flow of the current When this disturbance is realized the detector reports the anomaly The surface of the material being detected must be accessible to the current Various finishes and coverings may cause bad or weak readings An a...

Страница 19: ... Coil Delta18 and Omega18 Search Coil Delta38 and Omega38 Frame Coil Xi104 Gold nugget ø 5mm 18cm 17cm Gold coin ø 20mm 23cm 25cm Gold ring ø 22mm 17cm 34cm Silver coin ø 24mm 22cm 35cm Silver coin ø 40mm 31cm 45cm 1EUR coin 28cm 43cm Beverage can 0 5l 65cm 110cm 155 cm Gas can 20l 115cm 180cm 255 cm Steel barrel DIN EN 210 115cm 180cm 310 cm 5 2 GROUND BALANCING The ground balance of the Pulse No...

Страница 20: ...does take some practice Relax loosen up and find a comfortable grip on the handle Premature fatigue may result from gripping the handle too tightly an improperly adjusted rod or elbow support and limited body movement Hold the handle loosely Adjust the rod and elbow support for comfort and keep the elbow strap loose Use your arm shoulder and even your back a little to allow for a smooth even sweep...

Страница 21: ...t is receiving feedback There is a signal then it goes away why Check your ground balance most likely you adjusted it in the field and have reset the unit and balanced it out The size of the item may be extremely small or it may lie just within the range of the detector I hear a signal then I can t find it again why The coil may be touching or just about to touch the ground and give a signal that ...

Страница 22: ... Altenburg Germany we are developing and manufacturing geophysical detectors since 1998 Our unique detection technology helps to visualize buried objects and structures OKM GERMAN DETECTORS 49 3447 499300 0 49 162 419 2147 info okmdetectors com www okmdetectors com ...