Operating Modes
55
negative amplitude. The order is not important, it depends on the direction of movement of the
Supersensor. If you keep moving the probe from one side to another, these 2 signatures will change
continuously.
Take care to move the Supersensor slowly and at the same height above the ground and above a
detected object to get a clear signature.
The figure 7.13 represents a signature of a non-ferrous target. You can recognize that there is only a
positive amplitude (red). Additionally to the main amplitude there is another small peak, which is
typically for precious metals. Also here the order of amplitude and the small peak is not important and
depends on the scan direction.
The last of the typical signatures is represented in figure 7.14. It is the signature of all non-metallic
targets and structures. These can be voids, tunnels or buried plastic pipes or boxes. You can recognize
that there is only a negative amplitude (blue).
7.5 Empty Memory
The
Empty Memory mode is used to delete all data which is stored in the internal memory of the device.
If you confirm this option you will be asked again if you really want to delete all data. If you confirm now
by pressing Yes all data will be deleted and cannot be rebuilt or transferred to a computer.
OKM Ortungstechnik GmbH
Illustration 7.13: Signature of a non-ferromagnetic metal target
Non-ferromagnetic metals
Non-ferrous targets have a pure positive
signature.
Illustration 7.14: Signature of a non-metallic target
Non-metallic targets
All non-metallic items have a pure
negative signature.
Содержание eXp 4000
Страница 1: ...FS Future Series eXp 4000 Version 2 1 User s Manual ...
Страница 7: ...1 Introduction CHAPTER 1 Introduction ...
Страница 12: ......
Страница 33: ...3 Technical Specifications CHAPTER 3 Technical Specifications ...
Страница 35: ...4 Scope of Delivery CHAPTER 4 Scope of Delivery ...
Страница 40: ......